The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effect of arterial impedance changes on the end-systolic pressure-volume relation.
Abstract
To study the end-systolic pressure-volume relationship of left ventricle ejection against physiological afterload, we imposed seven simulated arterial impedances on excised canine left ventricles connected to a newly developed servo-pump system. We set each of the impedance parameters (resistance, capacitance, and characteristic impedance) to 50, 100, and 200% of normal value (resistance: 3 mm Hg sec/ml; capacitance: 0.4 ml/mm Hg; characteristic impedance: 0.2 mm Hg sec/ml), while leaving the other parameters normal. Under a given impedance, the end-systolic pressure-volume relationship was determined by preloading the ventricle at four different end-diastolic volumes. There was no significant change in the slope of the end-systolic pressure-volume relationship with changes in any of the afterloading impedance parameters. However, the volume intercept of the end-systolic pressure-volume relationship decreased significantly with resistance from 5.5 +/- 1.0 (SE) ml at resistance equal to 1.5 mm Hg sec/ml to 0.6 +/- 1.8 ml at resistance equal to 6 mm Hg sec/ml (P less than 0.01). The volume axis intercept also decreased with characteristic impedance, from 5.9 +/- 2.0 ml at a characteristic impedance of 0.1 mm Hg sec/ml to 5.4 +/- 2.1 ml at a characteristic impedance of 0.4 mm Hg sec/ml, (P less than 0.05). We conclude that the slope of the end-systolic pressure-volume relationship is insensitive to a wide range of changes in afterload impedance, but its volume intercept is dependent on resistance and characteristic impedance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUGA, H., & SAGAWA, K. (1974) · Circulation Research · doi:10.1161/01.res.35.1.117 · Cited by 1,330
Self-citation
Cited by
Kass, D. A., Maughan, W. L., Guo, Z. M., Kono, A., Sunagawa, K., & Sagawa, K. (1987) · Circulation · doi:10.1161/01.cir.76.6.1422 · Cited by 486
Self-citationVentricular efficiency predicted by an analytical model
Burkhoff, D., & Sagawa, K. (1986) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1986.250.6.r1021 · Cited by 405
Self-citationSingle-beat estimation of right ventricular end-systolic pressure-volume relationship
Brimioulle, S., Wauthy, P., Ewalenko, P., Rondelet, B., Vermeulen, F., Kerbaul, F., & Naeije, R. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01023.2002 · Cited by 346
The right ventricle: anatomy, physiology, and clinical importance
Dell'Italia, L. J. (1991) · Current Problems in Cardiology · doi:10.1016/0146-2806(91)90009-y · Cited by 300
The left ventricular dP/dtmax-end-diastolic volume relation in closed-chest dogs.
Little, W. C. (1985) · Circulation Research · doi:10.1161/01.res.56.6.808 · Cited by 297
Metadata
- Authors
- Maughan, W. L., Sunagawa, K., Burkhoff, D., & Sagawa, K.
- Venue
- Circulation Research
- Published
- 1984-05
- Volume
- 54
- Issue
- 5
- Pages
- 595-602
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2103058657
- Cited by
- 182
- References
- 1
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of arterial impedance changes on the end-systolic pressure-volume relation. https://app.cochat.ai/papers/10.1161/01.res.54.5.595
- The paper
- Maughan, W. L., Sunagawa, K., Burkhoff, D., & Sagawa, K. (1984). Effect of arterial impedance changes on the end-systolic pressure-volume relation. Circulation Research. https://doi.org/10.1161/01.res.54.5.595
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.