Mechanical properties of human pericardium. Differences in viscoelastic response when compared with canine pericardium.
Open accessThe DOI matches its Crossref record.
Abstract
Whereas most experiments on the mechanical function of the pericardium have been performed on dogs, very little is known about the applicability of those data to humans. To examine the tensile viscoelastic properties of fresh human pericardium, we have used the methods from our previous study of canine pericardium. Although the mechanical responses of canine and human pericardium were qualitatively similar, human pericardium displayed a significantly greater viscous character. Human pericardium was 7.3 times thicker than canine pericardium, but was more extensible in stress-strain tests, with lower stiffness at a given strain. The static (elastic) stiffness of human pericardium seems identical to that of canine pericardium; lower stiffness per unit thickness of the human tissue at predicted physiological stresses was almost exactly compensated by the greater wall thickness. This effect was also seen in data on fracture strength and stiffness. However, human pericardium displayed greater viscous responses than the canine tissue. This was seen in doubled cyclic hysteresis losses, and greater stress relaxation and creep. Our results suggest that experiments on the viscoelastic properties of canine pericardium may not be directly applicable to humans, especially where dynamic mechanical properties are most important: i.e., in studies of ventricular function and the time-course of pericardial effusions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Processing of collagen based biomaterials and the resulting materials properties
Meyer, M. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0647-0 · Cited by 539
Wan, W. K., Campbell, G., Zhang, Z. F., Hui, A. J., & Boughner, D. R. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10333 · Cited by 218
“Conventional fitting of relaxation data has previously utilized a linear logarithmic function of stress remaining versus time relationship.(27,28) This usually results in a linear fit with one slope, but two or more straight linear fits with distinctly different slopes have also been reported.”
MethodSelf-citationLiu, Q., Jiang, L., Shi, R., & Zhang, L. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.11.001 · Cited by 203
Mendoza-Novelo, B., Avila, E. E., Cauich-Rodríguez, J. V., Jorge-Herrero, E., Rojo, F. J., Guinea, G. V., & Mata-Mata, J. L. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.017 · Cited by 196
Metadata
- Authors
- Lee, J. M., & Boughner, D. R.
- Venue
- Circulation Research
- Published
- 1985-09
- Volume
- 57
- Issue
- 3
- Pages
- 475-481
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2088540528
- Cited by
- 90
- References
- 0
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical properties of human pericardium. Differences in viscoelastic response when compared with canine pericardium. https://app.cochat.ai/papers/10.1161/01.res.57.3.475
- The paper
- Lee, J. M., & Boughner, D. R. (1985). Mechanical properties of human pericardium. Differences in viscoelastic response when compared with canine pericardium. Circulation Research. https://doi.org/10.1161/01.res.57.3.475
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.