We calculated the wavelength of the atrial impulse in chronically instrumented conscious dogs by measuring both conduction velocity and refractory period: wavelength = refractory period X conduction velocity. Implantation of multiple stimulating and recording electrodes allowed wavelength determination at four different areas: the right and left parts of Bachmann's bundle and the free walls of the right and left atria. During programmed electrical stimulation, three types of arrhythmias were observed: rapid repetitive responses, atrial flutter, and atrial fibrillation. During normal rhythm, the wavelength of the atrial impulse varied between 14 and 18 cm. Premature beats had a shorter wavelength, depending on the degree of prematurity. Premature beats that evoked rapid repetitive responses showed a critical shortening of the wavelength below 12.3 cm. Episodes of atrial flutter were induced at a wavelength below 9.7 cm, while fibrillation occurred at wavelengths shorter than 7.8 cm. We correlated the induction of these arrhythmias with the values of refractory period, conduction velocity, and wavelength during control and during administration of several drugs. Intravenous administration of acetylcholine shortened the wavelength by 30-40%, mainly because of refractory period shortening. Both propafenone and lidocaine had strong but opposite effects on refractoriness and conduction and, consequently, little effect on the wavelength. Quinidine markedly prolonged the refractory period, but prolongation of wavelength was less because of a simultaneous decrease in conduction velocity. d-Sotalol also increased refractory period, but because it had no appreciable effect on conduction velocity, this drug was the most effective in prolongation of wavelength. Linear discriminant analysis of the data showed that the refractory period and the conduction velocity each were poor parameters to predict the occurrence of the different arrhythmias (predictive value 48% and 38%, respectively). The combination of both properties, however, as expressed in the wavelength, was a more reliable index that predicted the induction of the different arrhythmias correctly in 75% of the cases. We conclude that the wavelength is a useful parameter for evaluating antiarrhythmic drugs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.62.2.395

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 640

Metadata

Authors
Rensma, P. L., Allessie, M. A., Lammers, W. J., Bonke, F. I., & Schalij, M. J.
Venue
Circulation Research
Published
1988-02
Volume
62
Issue
2
Pages
395-410
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2117176106
Cited by
640
References
0
FWCI
6.11
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Length of excitation wave and susceptibility to reentrant atrial arrhythmias in normal conscious dogs. https://app.cochat.ai/papers/10.1161/01.res.62.2.395
The paper
Rensma, P. L., Allessie, M. A., Lammers, W. J., Bonke, F. I., & Schalij, M. J. (1988). Length of excitation wave and susceptibility to reentrant atrial arrhythmias in normal conscious dogs. Circulation Research. https://doi.org/10.1161/01.res.62.2.395

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.