CoChat

Passive properties of canine left ventricle: diastolic stiffness and restoring forces.

Nikolić, S, Yellin, E L, Tamura, K, Vetter, H, Tamura, T, Meisner, J S, Frater, R W · 1988 · Circulation Research
Cited by 228

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Left ventricular (LV) diastolic pressure-volume (P-V) relations arise from a complex interplay of active decay of force (i.e., relaxation), passive elastic myocardial properties, and time-varying inflow across the mitral orifice. This study was designed to quantify the passive properties of the intact ventricle and the effects of elastic recoil by separating filling from relaxation with a method of LV volume clamping with a remote-controlled mitral valve. Eleven open-chest fentanyl-anesthetized dogs were instrumented with aortic and mitral flow probes, LV and left atrium micromanometers, and a remote-controlled mitral valve. We prevented complete (end-systolic volume clamping) or partial filling at different times in diastole. The ventricle thus relaxed completely at different volumes, and we generated P-V coordinates for the passive ventricle that included negative, as well as positive, values of pressure. We then estimated ventricular volumes from ventricular weight in eight dogs, using regression equations based on data in the literature, to determine the equilibrium volume (V0), that is, volume at zero transmural pressure, in the working ventricle. We abandoned the traditional exponential approach and characterized by the P-V relation with a logarithmic approach that included maximum LV volume (Vm), minimum volume (Vd), and stiffness parameters (Sp and Sn) for the positive (p) and negative (n) phases: Pp = -Sp In[(Vm - V)/(Vm - V0)] and Pn = Sn In[(V - Vd)/(V0 - Vd)]. With this formulation, the chamber compliance, dP/dV, is normalized by the LV operating volume, and Sp and Sn are size-independent chamber stiffness parameters with the units of stress. In eight ventricles with LV weight = 131 +/- 20 g, Vm = 116 +/- 18 ml, V0 = 37 +/- 6 ml, and Vd = 13 +/- 2 ml, stiffness Sp = 14.6 mm Hg and Sn = 5.1 mm Hg were determined from the slopes of the log-linearized equations. Also, the duration of LV relaxation is increased by the process of ventricular filling (161 +/- 31 msec, filling versus 108 +/- 36 msec, nonfilling, measured from dP/dtmin, p less than 0.0001). We conclude that volume clamping is a useful method of studying restoring forces and that the logarithmic approach is conceptually and quantitatively useful in characterizing the passive properties of the intact ventricle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.62.6.1210

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 228

Metadata

Authors
Nikolić, S., Yellin, E. L., Tamura, K., Vetter, H., Tamura, T., Meisner, J. S., & Frater, R. W.
Venue
Circulation Research
Published
1988-06
Volume
62
Issue
6
Pages
1210-1222
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W1942977593
Cited by
228
References
19
FWCI
5.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.