Glower, D D, Spratt, J A, Snow, N D, Kabas, J S, Davis, J W, Olsen, C O, Tyson, G S, Sabiston, D C, Rankin, J S·1985·Circulation

Abstract

The Frank-Starling relationship generally has been examined with filling pressure as the index of preload, resulting in a curvilinear function that plateaus at higher filling pressures. To investigate this relationship further in the intact heart, 32 dogs were chronically instrumented with left ventricular and pleural micromanometers and with regional (10 dogs) or global (22 dogs) ultrasonic dimension transducers. Seven days after implantation, left ventricular pressure and regional or global dimensions were recorded in the conscious state. After autonomic blockade, preload was varied by vena caval occlusion. Myocardial function was assessed by calculating regional or global stroke work, and preload was measured as end-diastolic segment length or chamber volume. The relationship between stroke work and either end-diastolic segment length or chamber volume (termed the preload recruitable stroke work relationship) was highly linear in every study (mean r = .97) and could be quantified by a slope (MW) and x-intercept (LW). Previous nonlinear relationships between stroke work and filling pressure seemed to reflect the exponential diastolic pressure-volume curve. Over the physiologic range of systolic arterial pressures produced by infusion of nitroprusside or phenylephrine, no significant change was observed in MW or LW in the normal dog. Calcium infusion increased both regional and global MW by 71 +/- 19% and 65 +/- 9%, respectively (p less than .02), with no significant change in LW. To normalize for ventricular geometry and heart rate, stroke work was computed from circumferential stress-strain data and converted to myocardial power output, which was then plotted against end-diastolic circumferential strain. This relationship also was highly linear, and the slope, Mmp (mW/cm3 of myocardium), is proposed as a potential measure of intrinsic myocardial performance independent of loading, geometry, and heart rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.71.5.994

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 855

Metadata

Authors
Glower, D. D., Spratt, J. A., Snow, N. D., Kabas, J. S., Davis, J. W., Olsen, C. O., Tyson, G. S., Sabiston, D. C., & Rankin, J. S.
Venue
Circulation
Published
1985-05
Volume
71
Issue
5
Pages
994-1009
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2028982689
Cited by
855
References
27
FWCI
9.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Linearity of the Frank-Starling relationship in the intact heart: the concept of preload recruitable stroke work. https://app.cochat.ai/papers/10.1161/01.cir.71.5.994
The paper
Glower, D. D., Spratt, J. A., Snow, N. D., Kabas, J. S., Davis, J. W., Olsen, C. O., Tyson, G. S., Sabiston, D. C., & Rankin, J. S. (1985). Linearity of the Frank-Starling relationship in the intact heart: the concept of preload recruitable stroke work. Circulation. https://doi.org/10.1161/01.cir.71.5.994

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.