Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record.

Coronary pressure-function and steady-state pressure-flow relations during autoregulation in the unanesthetized dog.

Open access
Canty, J M·1988·Circulation Research

Abstract

The present study was intended to define the interrelation among endocardial flow, endocardial function, and coronary arterial pressure during spontaneous autoregulation in the left ventricle of chronically instrumented unanesthetized dogs. Steady-state sonomicrometric measurements of regional function and epicardial coronary artery pressure were used to determine the lower pressure limit of endocardial autoregulation while global indexes of myocardial demand remained constant. Transmural wall thickening in the circumflex bed remained unchanged (+/- 5% of control values) until coronary pressure fell below 39 +/- 5.6 (SD) mm Hg. Endocardial segment shortening was similarly constant until coronary pressure fell below 42 +/- 7.4 mm Hg. There was no significant change in endocardial flow as coronary pressure was reduced over the autoregulatory plateau from 84 to 49 mm Hg (1.05-0.99 ml/min/g, p = NS). Below the critical pressure limits, small additional reductions in pressure were associated with marked reductions in both endocardial flow and function. The coronary pressure-function relation was linear as well as steep in this range for both wall thickening (r = 0.94 +/- 0.05) and segment shortening (r = 0.96 +/- 0.03). Although the relation between endocardial flow and function showed more variability than pressure-function relations at low pressures, wall thickening reductions and endocardial flow reductions related on a nearly one-to-one basis. The present study establishes that the coronary pressure-function relation can be used to define the lower limit of endocardial autoregulation. It also indicates that the lower pressure limit of endocardial autoregulation is considerably less than in anesthetized animals (40 vs. 70 mm Hg) and that steady-state flow above this limit is controlled more tightly. Although these differences may relate to systemic hemodynamics, it seems likely that general anesthesia and/or acute surgical instrumentation alter coronary autoregulation under at least some experimental circumstances.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.63.4.821

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Canty, J. M.
Venue
Circulation Research
Published
1988-10
Volume
63
Issue
4
Pages
821-836
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2172190037
Cited by
174
References
0
FWCI
7.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Coronary pressure-function and steady-state pressure-flow relations during autoregulation in the unanesthetized dog. https://app.cochat.ai/papers/10.1161/01.res.63.4.821
The paper
Canty, J. M. (1988). Coronary pressure-function and steady-state pressure-flow relations during autoregulation in the unanesthetized dog. Circulation Research. https://doi.org/10.1161/01.res.63.4.821

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.