Coronary pressure-function and steady-state pressure-flow relations during autoregulation in the unanesthetized dog.
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The present study was intended to define the interrelation among endocardial flow, endocardial function, and coronary arterial pressure during spontaneous autoregulation in the left ventricle of chronically instrumented unanesthetized dogs. Steady-state sonomicrometric measurements of regional function and epicardial coronary artery pressure were used to determine the lower pressure limit of endocardial autoregulation while global indexes of myocardial demand remained constant. Transmural wall thickening in the circumflex bed remained unchanged (+/- 5% of control values) until coronary pressure fell below 39 +/- 5.6 (SD) mm Hg. Endocardial segment shortening was similarly constant until coronary pressure fell below 42 +/- 7.4 mm Hg. There was no significant change in endocardial flow as coronary pressure was reduced over the autoregulatory plateau from 84 to 49 mm Hg (1.05-0.99 ml/min/g, p = NS). Below the critical pressure limits, small additional reductions in pressure were associated with marked reductions in both endocardial flow and function. The coronary pressure-function relation was linear as well as steep in this range for both wall thickening (r = 0.94 +/- 0.05) and segment shortening (r = 0.96 +/- 0.03). Although the relation between endocardial flow and function showed more variability than pressure-function relations at low pressures, wall thickening reductions and endocardial flow reductions related on a nearly one-to-one basis. The present study establishes that the coronary pressure-function relation can be used to define the lower limit of endocardial autoregulation. It also indicates that the lower pressure limit of endocardial autoregulation is considerably less than in anesthetized animals (40 vs. 70 mm Hg) and that steady-state flow above this limit is controlled more tightly. Although these differences may relate to systemic hemodynamics, it seems likely that general anesthesia and/or acute surgical instrumentation alter coronary autoregulation under at least some experimental circumstances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Blood flow measurements with radionuclide-labeled particles
Heymann, M. A., Payne, B. D., Hoffman, J. I. E., & Rudolph, A. M. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(77)80005-4 · Cited by 2,036 · cited 2×
“Regional myocardial blood flow was calculated as previously described.(19) Normalization of regional flow.”
MethodFiber Orientation in the Canine Left Ventricle during Diastole and Systole
STREETER, D. D., SPOTNITZ, H. M., PATEL, D. P., ROSS, J., & SONNENBLICK, E. H. (1969) · Circulation Research · doi:10.1161/01.res.24.3.339 · Cited by 1,454
THE EFFECT OF CORONARY OCCLUSION ON MYOCARDIAL CONTRACTION
Tennant, R., & Wiggers, C. J. (1935) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1935.112.2.351 · Cited by 1,128
Johnson, P. C. (1986) · Circulation Research · doi:10.1161/01.res.59.5.483 · Cited by 413 · cited 1×
“Studies of autoregulation in other vascular beds have demonstrated attenuated autoregulation in response to anesthetic agents.(4) It is therefore possible that effects of anesthesia and/or acute surgical instrumentation alter coronary autoregulatory responses as they do the relation between endocardial flow and functi…”
BackgroundCorrelation between acute reductions in myocardial blood flow and function in conscious dogs.
Vatner, S. F. (1980) · Circulation Research · doi:10.1161/01.res.47.2.201 · Cited by 377 · cited 1×
“-(10)-(32)-(34) While some of this variation no doubt relates to anesthesia, differences also exist between endocardial flowfunction relations obtained in conscious animals when function is assessed by transmural wall thickening(10) as opposed to segment shortening.(9) Although beatto-beat variations in wall thickenin…”
BackgroundDepression of regional blood flow and wall thickening after brief coronary occlusions
Heyndrickx, G. R., Baig, H., Nellens, P., Leusen, I., Fishbein, M. C., & Vatner, S. F. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.234.6.h653 · Cited by 305
Sasayama, S., Franklin, D., Ross, J., Kemper, W. S., & McKown, D. (1976) · The American Journal of Cardiology · doi:10.1016/0002-9149(76)90800-6 · Cited by 293
Effect of Coronary Perfusion Pressure or Coronary Flow on Oxygen Usage of the Myocardium
Gregg, D. E. (1963) · Circulation Research · doi:10.1161/01.res.13.6.497 · Cited by 266
Matsuzaki, M., Gallagher, K. P., Kemper, W. S., White, F., & Ross, J. (1983) · Circulation · doi:10.1161/01.cir.68.1.170 · Cited by 259 · cited 1×
“The depression in function appeared similar to the reversible postischemic dysfunction reported after brief periods of total coronary occlusion(24) or prolonged partial occlusion.(25) This finding highlights an important methodologic consideration in studying autoregulation and/or the pressure-function relation on a r…”
ResultStability of heterogeneity of myocardial blood flow in normal awake baboons.
King, R. B., Bassingthwaighte, J. B., Hales, J. R. S., & Rowell, L. B. (1985) · Circulation Research · doi:10.1161/01.res.57.2.285 · Cited by 255
Cited by
Rosendorff, C., Black, H. R., Cannon, C. P., Gersh, B. J., Gore, J., Izzo, J. L., Kaplan, N. M., O’Connor, C. M., O’Gara, P. T., & Oparil, S. (2007) · Circulation · doi:10.1161/circulationaha.107.183885 · Cited by 757
Guidelines for experimental models of myocardial ischemia and infarction
Lindsey, M. L., Bolli, R., Canty, J. M., Du, X.-J., Frangogiannis, N. G., Frantz, S., Gourdie, R. G., Holmes, J. W., Jones, S. P., Kloner, R. A., et al. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00335.2017 · Cited by 526
Self-citationRegulation of Coronary Blood Flow
Goodwill, A. G., Dick, G. M., Kiel, A. M., & Tune, J. D. (2017) · Comprehensive Physiology · doi:10.1002/cphy.c160016 · Cited by 297
Rosendorff, C., Lackland, D. T., Allison, M., Aronow, W. S., Black, H. R., Blumenthal, R. S., Cannon, C. P., de Lemos, J. A., Elliott, W. J., Findeiss, L., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000207 · Cited by 259
Regulation of Coronary Blood Flow in Health and Ischemic Heart Disease
Duncker, D. J., Koller, A., Merkus, D., & Canty, J. M. (2015) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2014.12.002 · Cited by 255
Self-citationMyocardial hibernation: a delicate balance
Heusch, G., Schulz, R., & Rahimtoola, S. H. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01109.2004 · Cited by 200
Endothelial and neuro-humoral control of coronary blood flow in health and disease
Bassenge, E., & Heusch, G. (1990) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/3540528806_4 · Cited by 170
Coronary Blood Flow and Myocardial Ischemia
Weil, B. R., & Canty, J. M. (2013) · Essential Cardiology · doi:10.1007/978-1-4614-6705-2_22 · Cited by 164
Self-citation
Metadata
- Authors
- Canty, J. M.
- Venue
- Circulation Research
- Published
- 1988-10
- Volume
- 63
- Issue
- 4
- Pages
- 821-836
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2172190037
- Cited by
- 174
- References
- 21
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.