The DOI matches its Crossref record.
Cellular uncoupling can unmask dispersion of action potential duration in ventricular myocardium. A computer modeling study.
Abstract
Although slow conduction is a requirement for the preparation of sustained reentry, it alone is not sufficient for the initiation of reentry. Additionally, unidirectional block and recovery of excitability distal to the site of block must occur. Thus, a comprehensive description of the electrophysiological determinants of reentry must explain both slow conduction and unidirectional block. Although there is a growing body of research exploring the influence of axial resistivity and anisotropy on slow conduction, somewhat less is known about the relation of axial resistivity to spatial dispersion of action potential duration, a condition favorable to the development of unidirectional block. We hypothesized that when cells are well coupled, local differences in intrinsic action potential duration are not evident and that, as axial resistivity increases, local variation in action potential duration becomes manifest. We tested this hypothesis in a numerical model of electrical propagation in a grid of resistively coupled ionic current sources simulating a sheet of ventricular myocardium. Spatial dispersion of intrinsic action potential duration was simulated by varying the magnitude of the fully activated slow inward conductance in Beeler-Reuter membrane ionic kinetics. By then altering coupling resistance, we showed that dispersion of manifest action potential duration is masked in the setting of normal low-resistance cellular coupling and unmasked by increased axial resistance. When nonuniform anisotropy was simulated, dramatic pacing-site-dependent changes in both the pattern of activation and dispersion of action potential duration were noted. These findings may be important in understanding the mechanism of reentrant tachycardia initiation in the border zone of chronic, healed myocardial infarctions where evidence suggests that abnormal cellular coupling is the predominant electrophysiological derangement. In this study, we have shown, using a detailed ionic current-based model of cardiac electrical propagation, that changes in axial resistivity can modulate how spatial dispersion of intrinsic action potential duration is manifest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Potse, M., Dube, B., Richer, J., Vinet, A., & Gulrajani, R. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880875 · Cited by 470
Influence of anisotropic conduction properties in the propagation of the cardiac action potential
Valderrábano, M. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2007.03.014 · Cited by 125
Metadata
- Authors
- Lesh, M. D., Pring, M., & Spear, J. F.
- Venue
- Circulation Research
- Published
- 1989-11
- Volume
- 65
- Issue
- 5
- Pages
- 1426-1440
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2121378195
- Cited by
- 171
- References
- 0
- FWCI
- 5.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cellular uncoupling can unmask dispersion of action potential duration in ventricular myocardium. A computer modeling study. https://app.cochat.ai/papers/10.1161/01.res.65.5.1426
- The paper
- Lesh, M. D., Pring, M., & Spear, J. F. (1989). Cellular uncoupling can unmask dispersion of action potential duration in ventricular myocardium. A computer modeling study. Circulation Research. https://doi.org/10.1161/01.res.65.5.1426
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.