Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 276

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Protection of human left ventricular myocardium from cutting injury with 2,3-butanedione monoxime.

Mulieri, L A, Hasenfuss, G, Ittleman, F, Blanchard, E M, Alpert, N R·1989·Circulation Research

Abstract

To prevent dissection injury when cutting strip preparations from human left ventricular papillary muscle tissue, dissections were carried out with 2,3-butanedione monoxime (30 mM) added to Krebs-Ringer solution and followed by washout with normal solution. Eleven muscle strip preparations were dissected from left ventricular papillary muscle tissue of five patients undergoing mitral valve replacement surgery. The average muscle strip length was 6.8 +/- 1.4 mm, and cross-section area was 0.49 +/- 0.16 mm2. Peak twitch tension was 2.02 +/- 1.33 g/mm2 and ranged from 0.67 to 5.5 g/mm2 at an extracellular calcium concentration of 2.5 mM (21 degrees C, 0.16 Hz). In one muscle strip, which was stored in Krebs-Ringer plus 2,3-butanedione monoxime solution for 20 hours, peak twitch tension in normal Krebs-Ringer solution was 1.85 g/mm2. When temperature was increased from 21 degrees C, there was a continuous increase in peak twitch tension (by 38%) up to about 28 degrees C; then peak twitch tension decreased so that at 37 degrees C (n = 3) average peak twitch tension was lower than at 21 degrees C by 47%. The force-frequency relation exhibited a broad force plateau between 40 and 120 beats/min at 37 degrees C. The plateau was markedly narrowed at 30 degrees C and 24 degrees C. Thermopile heat measurements revealed appropriate waveform characteristics in high-resolution single-beat heat records indicating minimal surface cell damage. Thus, cardioplegia with 2,3-butanedione monoxime protects human left ventricular myocardium from dissection injury facilitating dissection and preservation of strip preparations with extraordinarily low cross-sectional areas and high peak twitch tensions. These preparations are suitable for myothermal and mechanical measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.65.5.1441

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 276

Metadata

Authors
Mulieri, L. A., Hasenfuss, G., Ittleman, F., Blanchard, E. M., & Alpert, N. R.
Venue
Circulation Research
Published
1989-11
Volume
65
Issue
5
Pages
1441-1449
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2144796862
Cited by
276
References
1
FWCI
3.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Protection of human left ventricular myocardium from cutting injury with 2,3-butanedione monoxime. https://app.cochat.ai/papers/10.1161/01.res.65.5.1441
The paper
Mulieri, L. A., Hasenfuss, G., Ittleman, F., Blanchard, E. M., & Alpert, N. R. (1989). Protection of human left ventricular myocardium from cutting injury with 2,3-butanedione monoxime. Circulation Research. https://doi.org/10.1161/01.res.65.5.1441

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.