The DOI matches its Crossref record.
Interaction of inhomogeneities of repolarization with anisotropic propagation in dog atria. A mechanism for both preventing and initiating reentry.
Open accessAbstract
Having found the regional differences in right atrial action potentials shown in an accompanying article, we tested two seemingly paradoxical hypotheses: 1) The spatial pattern of repolarization provides a protective mechanism against reentry, and 2) repolarization inhomogeneities interact with anisotropic discontinuous propagation to produce reentry. Measurement of multidimensional refractory periods demonstrated an anisotropic distribution within large bundles with the longest refractory periods in the medial upper crista terminalis (sinus node area), a distribution similar to that of action potential durations. Also, discontinuities of repolarization were found at muscle bundle junctions. Early premature impulses originating in the sinus node area propagated throughout the right atrial preparations without conduction disturbances or reentry. Conversely, early premature impulses that originated at sites distal to the sinus node area resulted in localized conduction block at multiple sites, which frequently produced complex conduction changes and reentry. The critical nature of the site of origin of a premature impulse in initiating reentry was related to locations where the steepest repolarization gradients occurred: within anisotropic bundles in the direction of highest axial resistance (across fibers) and at muscle bundle junctions that represented localized discontinuities of axial resistance. The multiple conduction abnormalities at localized sites interacted to produce different types of reentry at a larger size scale (25 mm2 to several cm2). In each case, neither repolarization inhomogeneities (leading circle concept) nor anisotropic discontinuous propagation was the only "mechanism" involved. That is, reentry at a macroscopic size scale occurred as a result of a combined repolarization-anisotropic discontinuous propagation mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blomström-Lundqvist, C., Scheinman, M. M., Aliot, E. M., Alpert, J. S., Calkins, H., Camm, A. J., Campbell, W. B., Haines, D. E., Kuck, K. H., Lerman, B. B., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.013 · Cited by 689
Khan, R., & Sheppard, R. (2006) · Immunology · doi:10.1111/j.1365-2567.2006.02336.x · Cited by 501
Konings, K. T. S., Smeets, J. L. R. M., Penn, O. C., Wellens, H. J. J., & Allessie, M. A. (1997) · Circulation · doi:10.1161/01.cir.95.5.1231 · Cited by 452
Schram, G., Pourrier, M., Melnyk, P., & Nattel, S. (2002) · Circulation Research · doi:10.1161/01.res.0000018627.89528.6f · Cited by 427
Magnetic resonance myocardial fiber-orientation mapping with direct histological correlation
Hsu, E. W., Muzikant, A. L., Matulevicius, S. A., Penland, R. C., & Henriquez, C. S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.5.h1627 · Cited by 386
Metadata
- Authors
- Spach, M. S., Dolber, P. C., & Heidlage, J. F.
- Venue
- Circulation Research
- Published
- 1989-12
- Volume
- 65
- Issue
- 6
- Pages
- 1612-1631
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1995182859
- Cited by
- 168
- References
- 0
- FWCI
- 3.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interaction of inhomogeneities of repolarization with anisotropic propagation in dog atria. A mechanism for both preventing and initiating reentry. https://app.cochat.ai/papers/10.1161/01.res.65.6.1612
- The paper
- Spach, M. S., Dolber, P. C., & Heidlage, J. F. (1989). Interaction of inhomogeneities of repolarization with anisotropic propagation in dog atria. A mechanism for both preventing and initiating reentry. Circulation Research. https://doi.org/10.1161/01.res.65.6.1612
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.