Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 676

The DOI matches its Crossref record.

Effects of fibrous cap thickness on peak circumferential stress in model atherosclerotic vessels.

Loree, H M, Kamm, R D, Stringfellow, R G, Lee, R T·1992·Circulation Research

Abstract

It is likely that factors other than stenosis severity predispose some atherosclerotic plaques to rupture. Because focal increases in circumferential stress may be an important mechanism of plaque rupture, we examined peak circumferential stress of atherosclerotic lesions by using finite element analysis based on idealized two-dimensional cross sections of diseased vessels similar to intravascular ultrasound images. The study was designed to test the hypothesis that subintimal plaque structural features such as thickness of the fibrous cap are more important factors in the distribution of stress in the plaque than stenosis severity. The analysis incorporated equilibrium biomechanical parameters from normal and diseased vessels and determined the stress distribution within the plaque at a mean luminal internal pressure of 110 mm Hg. With a constant luminal area reduction of 70%, maximum circumferential stress (sigma max) normalized to luminal pressure (sigma max/P) increased from 6.0 to 24.8 as the thickness of the lipid pool was increased from 38% to 54% of the plaque thickness because of the thinner fibrous cap over the lipid pool. When the lipid pool thickness was constant, increasing the stenosis severity from 70% to 91% by increasing the fibrous cap thickness decreased sigma max/P from 24.8 to 4.7. When no lipid pool was present and the stenosis severity was increased from 70% to 99%, sigma max/P decreased from 5.3 to 4.7. Thus, reducing the fibrous cap thickness dramatically increases peak circumferential stress in the plaque, whereas increasing the stenosis severity actually decreases peak stress in the plaque.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.71.4.850

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 676

Metadata

Authors
Loree, H. M., Kamm, R. D., Stringfellow, R. G., & Lee, R. T.
Venue
Circulation Research
Published
1992-10
Volume
71
Issue
4
Pages
850-858
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W1978684519
Cited by
676
References
0
FWCI
12.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of fibrous cap thickness on peak circumferential stress in model atherosclerotic vessels. https://app.cochat.ai/papers/10.1161/01.res.71.4.850
The paper
Loree, H. M., Kamm, R. D., Stringfellow, R. G., & Lee, R. T. (1992). Effects of fibrous cap thickness on peak circumferential stress in model atherosclerotic vessels. Circulation Research. https://doi.org/10.1161/01.res.71.4.850

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.