Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 197

The DOI matches its Crossref record.

Mapping the conversion of atrial flutter to atrial fibrillation and atrial fibrillation to atrial flutter. Insights into mechanisms.

Ortiz, J, Niwano, S, Abe, H, Rudy, Y, Johnson, N J, Waldo, A L·1994·Circulation Research

Abstract

It is not generally believed that there is a relation between atrial flutter, thought to be due to a single reentrant circuit, and atrial fibrillation, thought to be due to simultaneously circulating multiple-reentrant wave fronts. However, there are many reasons to suggest that these rhythms are more closely related than previously thought. To test the hypothesis that the length of an area of functional block in the right atrial free wall is critical to the conversion of atrial flutter to atrial fibrillation and of atrial fibrillation to atrial flutter, we studied spontaneous and ATP-induced conversion of stable atrial flutter to sustained atrial fibrillation and spontaneous conversion of sustained atrial fibrillation to stable atrial flutter. We studied 13 episodes of the conversion of stable atrial flutter to sustained atrial fibrillation and sustained atrial fibrillation to stable atrial flutter in seven dogs with sterile pericarditis. Six episodes were spontaneous and seven were ATP related. All episodes were studied by using a multisite mapping system to record 190 unipolar electrograms (converted in the software to 95 bipolar electrograms) from the right atrial free wall along with ECG lead II. Atrial flutter induction was attempted by atrial stimulation (S1S2 or S1S2S3) or by rapid atrial pacing for > or = 20 beats from selected sites at selected rates. For both the spontaneous and the ATP-related episodes, stable atrial flutter was defined as any episode of > or = 5 minutes, and sustained atrial fibrillation was any episode of > or = 1 minute. During all the episodes of stable atrial flutter, a line of functional block with a mean length of 24 +/- 4 mm was localized on the right atrial free wall. When the previously stable line of functional block decreased to a mean of 16 +/- 3 mm (P < .05), either spontaneously or after ATP administration (40 mg i.v.), the new line of functional block was not long enough to maintain stable atrial flutter, and conversion to atrial fibrillation resulted. This shortened line of functional block continued to change and migrate over the right atrial free wall throughout sustained atrial fibrillation. These observations were similar for both spontaneous and ATP-induced conversions. When sustained atrial fibrillation evolved to stable atrial flutter, there was reformation of a long line of functional block, long enough (> or = prior length) to create a stable reentrant circuit, which then captured the right atrial free wall and subsequently both atria.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.74.5.882

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 197

Metadata

Authors
Ortiz, J., Niwano, S., Abe, H., Rudy, Y., Johnson, N. J., & Waldo, A. L.
Venue
Circulation Research
Published
1994-05
Volume
74
Issue
5
Pages
882-894
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W1988808111
Cited by
197
References
0
FWCI
4.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mapping the conversion of atrial flutter to atrial fibrillation and atrial fibrillation to atrial flutter. Insights into mechanisms. https://app.cochat.ai/papers/10.1161/01.res.74.5.882
The paper
Ortiz, J., Niwano, S., Abe, H., Rudy, Y., Johnson, N. J., & Waldo, A. L. (1994). Mapping the conversion of atrial flutter to atrial fibrillation and atrial fibrillation to atrial flutter. Insights into mechanisms. Circulation Research. https://doi.org/10.1161/01.res.74.5.882

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.