Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 616

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Resistance to blood flow in microvessels in vivo.

Open access
Pries, A R, Secomb, T W, Gessner, T, Sperandio, M B, Gross, J F, Gaehtgens, P·1994·Circulation Research

Abstract

Resistance to blood flow through peripheral vascular beds strongly influences cardiovascular function and transport to tissue. For a given vascular architecture, flow resistance is determined by the rheological behavior of blood flowing through microvessels. A new approach for calculating the contribution of blood rheology to microvascular flow resistance is presented. Morphology (diameter and length), flow velocity, hematocrit, and topological position were determined for all vessel segments (up to 913) of terminal microcirculatory networks in the rat mesentery by intravital microscopy. Flow velocity and hematocrit were also predicted from mathematical flow simulations, in which the assumed dependence of flow resistance on diameter, hematocrit, and shear rate was optimized to minimize the deviation between measured and predicted values. For microvessels with diameters below approximately 40 microns, the resulting flow resistances are markedly higher and show a stronger dependence on hematocrit than previously estimated from measurements of blood flow in narrow glass tubes. For example, flow resistance in 10-microns microvessels at normal hematocrit is found to exceed that of a corresponding glass tube by a factor of approximately 4. In separate experiments, flow resistance of microvascular networks was estimated from direct measurements of total pressure drop and volume flow, at systemic hematocrits intentionally varied from 0.08 to 0.68. The results agree closely with predictions based on the above-optimized resistance but not with predictions based on glass-tube data. The unexpectedly high flow resistance in small microvessels may be related to interactions between blood components and the inner vessel surface that do not occur in smooth-walled tubes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.75.5.904

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 616

Metadata

Authors
Pries, A. R., Secomb, T. W., Gessner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P.
Venue
Circulation Research
Published
1994-11
Volume
75
Issue
5
Pages
904-915
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2126410943
Cited by
616
References
9
FWCI
6.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Resistance to blood flow in microvessels in vivo. https://app.cochat.ai/papers/10.1161/01.res.75.5.904
The paper
Pries, A. R., Secomb, T. W., Gessner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P. (1994). Resistance to blood flow in microvessels in vivo. Circulation Research. https://doi.org/10.1161/01.res.75.5.904

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.