Resistance to blood flow in microvessels in vivo.
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Resistance to blood flow through peripheral vascular beds strongly influences cardiovascular function and transport to tissue. For a given vascular architecture, flow resistance is determined by the rheological behavior of blood flowing through microvessels. A new approach for calculating the contribution of blood rheology to microvascular flow resistance is presented. Morphology (diameter and length), flow velocity, hematocrit, and topological position were determined for all vessel segments (up to 913) of terminal microcirculatory networks in the rat mesentery by intravital microscopy. Flow velocity and hematocrit were also predicted from mathematical flow simulations, in which the assumed dependence of flow resistance on diameter, hematocrit, and shear rate was optimized to minimize the deviation between measured and predicted values. For microvessels with diameters below approximately 40 microns, the resulting flow resistances are markedly higher and show a stronger dependence on hematocrit than previously estimated from measurements of blood flow in narrow glass tubes. For example, flow resistance in 10-microns microvessels at normal hematocrit is found to exceed that of a corresponding glass tube by a factor of approximately 4. In separate experiments, flow resistance of microvascular networks was estimated from direct measurements of total pressure drop and volume flow, at systemic hematocrits intentionally varied from 0.08 to 0.68. The results agree closely with predictions based on the above-optimized resistance but not with predictions based on glass-tube data. The unexpectedly high flow resistance in small microvessels may be related to interactions between blood components and the inner vessel surface that do not occur in smooth-walled tubes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE VISCOSITY OF THE BLOOD IN NARROW CAPILLARY TUBES
Fåhræus, R., & Lindqvist, T. (1931) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1931.96.3.562 · Cited by 1,268
In vivo measurements of “apparent viscosity” and microvessel hematocrit in the mesentery of the cat
Lipowsky, H. H., Usami, S., & Chien, S. (1980) · Microvascular Research · doi:10.1016/0026-2862(80)90050-3 · Cited by 398
Red cell distribution at microvascular bifurcations
Pries, A. R., Ley, K. F., Claassen, M., & Gaehtgens, P. A. L. (1989) · Microvascular Research · doi:10.1016/0026-2862(89)90018-6 · Cited by 392
Self-citationBiophysical Behavior of Red Cells in Suspensions
CHIEN, S. (1975) · The Red Blood Cell · doi:10.1016/b978-0-12-677202-9.50019-8 · Cited by 349
Interactions among erythrocytes under shear.
Brooks, D. E., Goodwin, J. W., & Seaman, G. V. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.28.2.172 · Cited by 217
Zweifach, B. W. (1974) · Circulation Research · doi:10.1161/01.res.34.6.858 · Cited by 166
Comparative hemorheology—Hematological implications of species differences in blood viscosity
Chien, S., Usami, S., Dellenback, R. J., & Bryant, C. A. (1971) · Biorheology · doi:10.3233/bir-1971-8106 · Cited by 145
Braide, M., AMUNDSON, B., Chien, S., & BAGGE, U. (1984) · Microvascular Research · doi:10.1016/0026-2862(84)90064-5 · Cited by 117
The effects of leukocytes on blood flow in a model skeletal muscle capillary network
Warnke, K. C., & Skalak, T. C. (1990) · Microvascular Research · doi:10.1016/0026-2862(90)90012-g · Cited by 47
Cited by
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (2000) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240000307 · Cited by 898
Self-citationMICROCIRCULATION AND HEMORHEOLOGY
Popel, A. S., & Johnson, P. C. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.37.042604.133933 · Cited by 831
Vink, H., & Duling, B. R. (1996) · Circulation Research · doi:10.1161/01.res.79.3.581 · Cited by 615
Microvascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
Fernández-Klett, F., Offenhauser, N., Dirnagl, U., Priller, J., & Lindauer, U. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1011321108 · Cited by 399
“Exhaustion of this layer by subtle decreases in capillary diameter might have a profound impact on resistance to RBC flow (14).”
BackgroundMicrovascular blood viscosity in vivo and the endothelial surface layer
Pries, A. R., & Secomb, T. W. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00297.2005 · Cited by 349
Self-citationDesign Principles of Vascular Beds
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1995) · Circulation Research · doi:10.1161/01.res.77.5.1017 · Cited by 321
Self-citationTsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci58753 · Cited by 297
Causes and Effects of Heterogeneous Perfusion in Tumors
Gillies, R. J., Schomack, P. A., Secomb, T. W., & Raghunand, N. (1999) · Neoplasia · doi:10.1038/sj.neo.7900037 · Cited by 283
Self-citationBlood Flow and Cell-Free Layer in Microvessels
FEDOSOV, D. A., CASWELL, B., POPEL, A. S., & KARNIADAKIS, G. E. (2010) · Microcirculation · doi:10.1111/j.1549-8719.2010.00056.x · Cited by 277
Structural adaptation and stability of microvascular networks: theory and simulations
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.2.h349 · Cited by 275
Self-citationA two‐phase model for flow of blood in narrow tubes with increased effective viscosity near the wall
Sharan, M., & Popel, A. S. (2001) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2001038005006005 · Cited by 249
“Further, this model in glycocalyx-lined arterioles does not fully explain the high apparent viscosity obtained from the “in vivo viscosity law” [19].”
Scaling laws of vascular trees: of form and function
Kassab, G. S. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00579.2005 · Cited by 221
“(30) provided a validated model of the dependence of blood viscosity on the diameter and shear rate of flow to describe the Fahraeus-Lindqvist effect and the non-Newtonian properties of blood, which was used in the present study.”
MethodJayaweera, A. R., Wei, K., Coggins, M., Bin, J. P., Goodman, C., & Kaul, S. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.6.h2363 · Cited by 186
“In contradistinction, the viscosity term is the most important determinant of microvascular flow (25).”
BackgroundInfluentialStructural adaptation of microvascular networks: functional roles of adaptive responses
Pries, A. R., Reglin, B., & Secomb, T. W. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.281.3.h1015 · Cited by 174
“In two networks, an additional scan using strobe asynchronous illumination was made to allow the determination of blood flow velocity (Vb) in each segment with a digital image analysis system (31).”
MethodSelf-citationA circular cross-section PDMS microfluidics system for replication of cardiovascular flow conditions
Fiddes, L. K., Raz, N., Srigunapalan, S., Tumarkan, E., Simmons, C. A., Wheeler, A. R., & Kumacheva, E. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.082 · Cited by 170
“Furthermore, in rectangular channels the area of contact of confined cells with the microchannel walls is reduced, and the flow profile of the cells differs from that in a channel with a circular cross-section [13,14].”
BackgroundThe cell-free layer in microvascular blood flow
Kim, S., Ong, P. K., Yalcin, O., Intaglietta, M., & Johnson, P. C. (2009) · Biorheology · doi:10.3233/bir-2009-0530 · Cited by 159
Metadata
- Authors
- Pries, A. R., Secomb, T. W., Gessner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P.
- Venue
- Circulation Research
- Published
- 1994-11
- Volume
- 75
- Issue
- 5
- Pages
- 904-915
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2126410943
- Cited by
- 616
- References
- 9
- FWCI
- 6.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.