Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 208

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The Stochastic Nature of Cardiac Propagation at a Microscopic Level: Electrical Description of Myocardial Architecture and Its Application to Conduction

Spach, Madison S., Heidlage, J. Francis·1995·Circulation Research

Abstract

Abstract The object of this study is to present evidence that the myocardial architecture creates inhomogeneities of electrical load at the cellular level that cause cardiac propagation to be stochastic in nature; ie, the excitatory events during propagation are constantly changing and disorderly in the sense of varying intracellular events and delays between cells. At a macroscopic level, however, these stochastic events become averaged and appear consistent with a continuous medium. We examined this concept in a two-dimensional (2D) model of myocardial architecture by exploring whether experimentally observed V̇ max variability reflected different patterns of intracellular excitation events and junctional delays. The patterns of V̇ max variability at randomly chosen intracellular sites were similar experimentally and in the 2D model. The 2D cellular model produced marked variability in gap junction delays; however, on the average, different gap junctions were used for cell-to-cell charge flow during conduction in different directions. During longitudinal propagation (LP), the velocity increased from the proximal to the distal end of each myocyte, and V̇ max was lowest proximally, increased to a maximum at the distal fourth of the cell, and decreased distally. Transverse propagation (TP) produced rapid intracellular conduction with variable intracellular excitation sequences. TP V̇ max was greater than LP V̇ max in most subcellular regions, but near the ends of some myocytes, a reversed “TP>LP V̇ max ” relation occurred. Total charge carried by the sodium current varied inversely with V̇ max , demonstrating feedback effects of cellular loading on the subcellular sodium current and the kinetics of the sodium channels. The results suggest that the stochastic nature of normal propagation at a microscopic level provides a considerable protective effect against arrhythmias by reestablishing the general trend of wave-front movement after small variations in excitation events occur.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.76.3.366

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 208

Metadata

Authors
Spach, M. S., & Heidlage, J. F.
Venue
Circulation Research
Published
1995-03
Volume
76
Issue
3
Pages
366-380
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2102289558
Cited by
208
References
2
FWCI
10.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Stochastic Nature of Cardiac Propagation at a Microscopic Level: Electrical Description of Myocardial Architecture and Its Application to Conduction. https://app.cochat.ai/papers/10.1161/01.res.76.3.366
The paper
Spach, M. S., & Heidlage, J. F. (1995). The Stochastic Nature of Cardiac Propagation at a Microscopic Level: Electrical Description of Myocardial Architecture and Its Application to Conduction. Circulation Research. https://doi.org/10.1161/01.res.76.3.366

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.