CoChat
Cited by 261

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Dye Tracers Define Differential Endothelial and Smooth Muscle Coupling Patterns Within the Arteriolar Wall

Little, T. L., Xia, J., Duling, B. R. · 1995 · Circulation Research

Abstract

Abstract Dye tracers were chosen, based on net charge, chemical structure, and reactive groups, to test for the existence of and to provide novel insight into channel selectivities of junctional pathways connecting smooth muscle and endothelial cells of the arteriolar wall. Dyes were injected into individual smooth muscle or endothelial cells of hamster cheek pouch arterioles using microiontophoresis. Coupling, independent of tracer net charge, was seen both within and between cell layers. Endothelial cells were well coupled by all of the tested dyes. Smooth muscle junctions appeared less effective in dye transfer than endothelial junctions. Lucifer yellow was confirmed to be a poor tracer of smooth muscle gap junctions, and remarkably this dye and other related sulfate-containing molecules interfered with dye movement through smooth muscle but not endothelial junctions. Myoendothelial junctions showed a striking polarity of dye movement, with dye transfer from endothelial to smooth muscle cells but little or no transfer in the reverse direction. Because the dyes have size and charge characteristics similar to those of known cellular second messengers, these findings have important implications for cell-cell signaling in the vessel wall.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.76.3.498

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 261

Metadata

Authors
Little, T. L., Xia, J., & Duling, B. R.
Venue
Circulation Research
Published
1995-03
Volume
76
Issue
3
Pages
498-504
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2005284425
Cited by
261
References
20
FWCI
5.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.