The DOI matches its Crossref record.
Modulation of Cerebral Arteriolar Diameter by Intraluminal Flow and Pressure
Abstract
We determined whether cerebral arterioles in vitro adjust their diameters in response to changes in intraluminal flow rate and pressure. Intracerebral arterioles (38- to 55-μm diameter) were isolated from Sprague-Dawley rats and cannulated with a perfusion system that permitted separate control of intraluminal pressure and flow rates. Increasing pressure at 0 flow, in 20 mm Hg steps from 20 to 100 mm Hg, resulted in myogenic constriction, which was greatest at 60 mm Hg (≈20%). Increasing flow rate at a constant pressure of 60 mm Hg elicited a biphasic response. At flow rates of up to 10 μL/min, the arterioles dilated by up to 14.5±2.2% of their control diameter. At higher (>10 μL/min) flow rates, however, a progressive restoration of resting diameter was observed. Application of the nitric oxide synthase inhibitor NG-monomethyl-l-arginine (L-NMMA, 0.1 mmol/L) caused a 15.4±1.7% decrease in control diameter (at 60 mm Hg, zero flow). Although L-NMMA did not affect the responses to increases in pressure or to vasodilators (adenosine and pH 6.8 buffer), it abolished the dilator responses to flow rate increases and to acetylcholine. In contrast, inhibition of prostaglandin synthesis by indomethacin (10 μmol/L) had no effect on flow-induced dilation. These results show that changes in intraluminal flow rates and pressure can independently influence cerebral arteriolar tone and suggest that the flow-induced dilator responses of cerebral arterioles are mediated by an arginine metabolite, such as nitric oxide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A blood–brain barrier overview on structure, function, impairment, and biomarkers of integrity
Kadry, H., Noorani, B., & Cucullo, L. (2020) · Fluids and Barriers of the CNS · doi:10.1186/s12987-020-00230-3 · Cited by 1,853
Regulation of cerebral blood flow in humans: physiology and clinical implications of autoregulation
Claassen, J. A. H. R., Thijssen, D. H. J., Panerai, R. B., & Faraci, F. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00022.2020 · Cited by 915
Regulation of the Cerebral Circulation: Role of Endothelium and Potassium Channels
FARACI, F. M., & HEISTAD, D. D. (1998) · Physiological Reviews · doi:10.1152/physrev.1998.78.1.53 · Cited by 780
Perivascular nerves and the regulation of cerebrovascular tone
Hamel, E. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00954.2005 · Cited by 724
The neurovascular unit - concept review
Muoio, V., Persson, P. B., & Sendeski, M. M. (2014) · Acta Physiologica · doi:10.1111/apha.12250 · Cited by 564
Metadata
- Authors
- Ngai, A. C., & Winn, H. R.
- Venue
- Circulation Research
- Published
- 1995-10
- Volume
- 77
- Issue
- 4
- Pages
- 832-840
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2167921651
- Cited by
- 160
- References
- 0
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modulation of Cerebral Arteriolar Diameter by Intraluminal Flow and Pressure. https://app.cochat.ai/papers/10.1161/01.res.77.4.832
- The paper
- Ngai, A. C., & Winn, H. R. (1995). Modulation of Cerebral Arteriolar Diameter by Intraluminal Flow and Pressure. Circulation Research. https://doi.org/10.1161/01.res.77.4.832
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.