Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 185

The DOI matches its Crossref record.

Identification of a Putative Microvascular Oxygen Sensor

Harder, David R., Narayanan, Jayashree, Birks, Eric K., Liard, Jean Francois, Imig, John D., Lombard, Julian H., Lange, Andrew R., Roman, Richard J. · 1996 · Circulation Research

Abstract

The vascular response to changes in oxygen levels in the blood and tissue is a highly adaptive physiological response that functions to match tissue oxygen supply to metabolic demand. Defining the cellular mechanisms that can sense physiologically relevant changes in P o2 and adjust vascular diameter are vital to our understanding of this process. A cytochrome P450 (P450) enzyme of the 4A family of ω-hydroxylases was localized in renal microvessels, renal cortex, and a striated muscle microvascular bed (cremaster) of the rat. In the presence of molecular oxygen, this P450 enzyme catalyzes formation of 20-HETE from arachidonic acid (AA). Prior studies have shown that 20-HETE potently contracts renal and cerebral arteries and arterioles. The present study demonstrates that 20-HETE constricts striated muscle arterioles as well. In both intact renal microvessels and enriched renal cortical microsomal enzyme preparations, the formation of 20-HETE was linearly dependent on P o2 between 20 and 140 mm Hg. Homogenates of cremaster tissue produced 20-HETE when incubated with AA. They also expressed message for P450 4A enzyme, as determined by Southern and Western blots. Administration of 17-octadecynoic acid (17-ODYA), which is a P450 4A inhibitor, attenuated the constriction of third-order cremasteric arterioles in response to elevation of superfusion solution P o2 from ≈3 to 5 mm Hg to ≈35 mm Hg. 17-ODYA had no effect on basal vascular tone or response of cremaster arterioles to vasoactive compounds. These results demonstrate the existence of P450 ω-hydroxylase activity and 20-HETE formation in the vasculature and parenchyma of at least two microvascular beds. Our data suggest that a P450 enzyme of the 4A family has the potential to function as an oxygen sensor in mammalian microcirculatory beds and to regulate arteriolar caliber by generating 20-HETE in an oxygen-dependent manner.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.79.1.54

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Harder, D. R., Narayanan, J., Birks, E. K., Liard, J. F., Imig, J. D., Lombard, J. H., Lange, A. R., & Roman, R. J.
Venue
Circulation Research
Published
1996-07
Volume
79
Issue
1
Pages
54-61
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W1993405930
Cited by
185
References
0
FWCI
4.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identification of a Putative Microvascular Oxygen Sensor. https://app.cochat.ai/papers/10.1161/01.res.79.1.54
The paper
Harder, D. R., Narayanan, J., Birks, E. K., Liard, J. F., Imig, J. D., Lombard, J. H., Lange, A. R., & Roman, R. J. (1996). Identification of a Putative Microvascular Oxygen Sensor. Circulation Research. https://doi.org/10.1161/01.res.79.1.54

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.