The DOI matches its Crossref record.
Hypoxia-Induced Inhibition of Adenosine Kinase Potentiates Cardiac Adenosine Release
Abstract
Abstract To elucidate the physiological role of the AMP-adenosine metabolic cycle and to investigate the relation between AMP and adenosine formation, the O 2 supply of isolated guinea pig hearts was varied (95% to 10% O 2 ). The net adenosine formation rate (AMP→adenosine) and coronary venous effluent adenosine release rate were measured; free cytosolic AMP was determined by 31 P-nuclear magnetic resonance. Switching from 95% to 40% O 2 increased free AMP and adenosine formation 4-fold, whereas free cytosolic adenosine and venous adenosine release rose 15- to 20-fold. In the AMP range from 200 to 3000 nmol/L, there was a linear correlation between free AMP and adenosine formation ( R 2 =.71); however, adenosine release increased several-fold more than formation. At 95% O 2 , only 6% of the adenosine formed was released; however, this fraction increased to 22% at 40% O 2 , demonstrating reduced adenosine salvage. Selective blockade of adenosine deaminase and adenosine kinase indicated that flux through adenosine kinase decreased from 85% to 35% of adenosine formation in hypoxia. Mathematical model analysis indicated that this apparent decrease in enzyme activity was not due to saturation but to the inhibition of adenosine kinase activity to 6% of the basal levels. The data show (1) that adenosine formation is proportional to the AMP substrate concentration and (2) that hypoxia decreases adenosine kinase activity, thereby shunting myocardial adenosine from the salvage pathway to venous release. In conclusion, because of the normal high turnover of the AMP-adenosine metabolic cycle, hypoxia-induced inhibition of adenosine kinase causes the amplification of small changes in free AMP into a major rise in adenosine. This mechanism plays an important role in the high sensitivity of the cardiac adenosine system to impaired oxygenation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
International Union of Pharmacology. XXV. Nomenclature and Classification of Adenosine Receptors
Fredholm, B. B., IJzerman, A. P., Jacobson, K. A., Klotz, K.-N., & Linden, J. (2001) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01511-4 · Cited by 2,585
James, S. J., Cutler, P., Melnyk, S., Jernigan, S., Janak, L., Gaylor, D. W., & Neubrander, J. A. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/80.6.1611 · Cited by 955
CNS energy metabolism as related to function
Ames, A. (2000) · Brain Research Reviews · doi:10.1016/s0165-0173(00)00038-2 · Cited by 663
Immunological mechanisms of the antitumor effects of supplemental oxygenation
Hatfield, S. M., Kjaergaard, J., Lukashev, D., Schreiber, T. H., Belikoff, B., Abbott, R., Sethumadhavan, S., Philbrook, P., Ko, K., Cannici, R., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa1260 · Cited by 600
Regulation of immune cells by local-tissue oxygen tension: HIF1α and adenosine receptors
Sitkovsky, M., & Lukashev, D. (2005) · Nature Reviews Immunology · doi:10.1038/nri1685 · Cited by 518
Metadata
- Authors
- Decking, U. K. M., Schlieper, G., Kroll, K., & Schrader, J.
- Venue
- Circulation Research
- Published
- 1997-08
- Volume
- 81
- Issue
- 2
- Pages
- 154-164
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2036205982
- Cited by
- 265
- References
- 0
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hypoxia-Induced Inhibition of Adenosine Kinase Potentiates Cardiac Adenosine Release. https://app.cochat.ai/papers/10.1161/01.res.81.2.154
- The paper
- Decking, U. K. M., Schlieper, G., Kroll, K., & Schrader, J. (1997). Hypoxia-Induced Inhibition of Adenosine Kinase Potentiates Cardiac Adenosine Release. Circulation Research. https://doi.org/10.1161/01.res.81.2.154
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.