The DOI matches its Crossref record.
Connexin45 Expression Is Preferentially Associated With the Ventricular Conduction System in Mouse and Rat Heart
Open accessAbstract
Abstract —Cardiac myocytes are electrically coupled by gap junctions, clusters of low-resistance intercellular channels composed of connexins. Variations in the quantities and spatial distribution of different connexin types have been implicated in regional differentiation of electrophysiological properties in the heart. Although independent studies have demonstrated that connexin43 is abundant in working ventricular myocardium and that connexin40 is preferentially expressed in the atrioventricular conduction system of a number of species, information on the spatial distribution of connexin45 in the heart is limited to data obtained using an antibody raised to a single peptide sequence. In the present study, we report on the production and characterization of a new anti-connexin45 antibody and its application to the investigation of connexin45 expression in mouse and rat myocardium. The affinity-purified antiserum, raised in guinea pig to residues 354 to 367 of human connexin45, recognized a single 45-kD band on Western blots of HeLa cells transfected to express connexin45 and gave punctate immunolabeling at the cell borders, demonstrated by freeze-fracture cytochemistry to represent gap junctions. Only low levels of connexin45 mRNA were detected on Northern blots of mouse and rat cardiac tissues, and connexin45 protein levels were below the limit of detection on Western blots. Confocal microscopy of immunolabeled ventricular tissue revealed that the major part of the working myocardium was immunonegative for connexin45. A clearly defined zone containing connexin45-expressing cells was, however, localized to the endocardial surface, overlapping with connexin40-expressing myocytes of the conduction system. As these results contrast with the prevailing view that connexin45 is widely distributed in working ventricular myocytes, we compared the immunolabeling pattern obtained with a commercially supplied anti-connexin45 antiserum raised against the same peptide that was used in previous studies. The commercial connexin45 antiserum gave widespread labeling throughout the ventricular myocardium, but this labeling was inhibited by a six–amino acid peptide matching part of the connexin43 sequence, indicating cross-reaction of the commercial connexin45 antiserum with connexin43 in the tissue. Further evidence for such cross-reactivity came from observations on connexin43-transfected cells, which gave positive immunolabeling with the commercial anti-connexin45 antiserum. Our demonstration of a specific association of connexin45 with connexin40-expressing myocytes in rat and mouse ventricle raises the possibility that connexin45 contributes to the modulation of electrophysiological properties in the ventricular conduction system and highlights the need for reappraisal of the distribution and role of connexin45 in other species.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The sinoatrial node, a heterogeneous pacemaker structure
Boyett, M. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00135-8 · Cited by 698
Remodelling of gap junctions and connexin expression in diseased myocardium
Severs, N. J., Bruce, A. F., Dupont, E., & Rothery, S. (2008) · Cardiovascular Research · doi:10.1093/cvr/cvn133 · Cited by 560
Self-citationCoupling of Cardiac Electrical Activity Over Extended Distances by Fibroblasts of Cardiac Origin
Gaudesius, G., Miragoli, M., Thomas, S. P., & Rohr, S. (2003) · Circulation Research · doi:10.1161/01.res.0000089258.40661.0c · Cited by 505
Schram, G., Pourrier, M., Melnyk, P., & Nattel, S. (2002) · Circulation Research · doi:10.1161/01.res.0000018627.89528.6f · Cited by 427
Gap Junctions in Cardiovascular Disease
Jongsma, H. J., & Wilders, R. (2000) · Circulation Research · doi:10.1161/01.res.86.12.1193 · Cited by 403
Metadata
- Authors
- Coppen, S. R., Dupont, E., Rothery, S., & Severs, N. J.
- Venue
- Circulation Research
- Published
- 1998-02-09
- Volume
- 82
- Issue
- 2
- Pages
- 232-243
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2149455838
- Cited by
- 227
- References
- 0
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Connexin45 Expression Is Preferentially Associated With the Ventricular Conduction System in Mouse and Rat Heart. https://app.cochat.ai/papers/10.1161/01.res.82.2.232
- The paper
- Coppen, S. R., Dupont, E., Rothery, S., & Severs, N. J. (1998). Connexin45 Expression Is Preferentially Associated With the Ventricular Conduction System in Mouse and Rat Heart. Circulation Research. https://doi.org/10.1161/01.res.82.2.232
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.