Reentry and Fibrillation in the Mouse Heart: A Challenge to the Critical Mass Hypothesis

Vaidya, Dhananjay, Morley, Gregory E., Samie, Faramarz H., Jalife, José·1999·Circulation Research

Abstract

Abstract —The idea that fibrillation is only possible in hearts exceeding a critical size was introduced by W. Garrey >80 years ago and has since been generally accepted. In ventricular tissue, this critical size was originally estimated to be 400 mm 2 . Recent estimates suggest that the critical size required for sustained reentry is ≈100 to 200 mm 2 , whereas 6 times this area is required for ventricular fibrillation. According to these estimates, fibrillation is not possible in the mouse heart, where the ventricular surface area is ≈100 mm 2 . To test whether sustained ventricular fibrillation could be induced in such an area, we used a high-speed video imaging system and a voltage-sensitive dye to quantify electrical activity on the epicardial surface of the Langendorff-perfused adult mouse heart. In 6 hearts, measurements during ventricular pacing at a basic cycle length (BCL) of 120 ms yielded maximum and minimum conduction velocities (CV max and CV min ) of 0.63±0.04 and 0.38±0.02 mm/ms, respectively. At a BCL of 80 ms, CV max and CV min changed to 0.55±0.03 and 0.34±0.02 mm/ms. Action potential durations (APDs), measured at 70% repolarization at those pacing frequencies were found to be 44.5±2.9 and 40.4±2.6 ms, respectively. The wavelengths (CV×APD) were calculated to be 28.6±3.4 mm in the CV max direction and 16.8±1.5 mm in the CV min direction at BCL 120 ms. Wavelengths were significantly reduced ( P <0.05) at BCL 80 ms (CV max , 22.2±1.8 mm; CV min , 13.7±0.9 mm). In 5 hearts, stationary vortex-like reentry organized by single rotors (4 of 5 hearts) or by pairs of rotors (1 of 5 hearts) was induced by burst pacing. In the ECG, the activity manifested as sustained monomorphic tachycardia. Detailed analysis showed that the local CVs were reduced in the vicinity of the rotor center, which allowed the reentry to take place within a smaller area than was calculated from wavelength measurements during pacing. In 4 of 7 hearts, burst pacing resulted in a polymorphic ECG pattern indistinguishable from ventricular fibrillation. These data challenge the critical mass hypothesis by demonstrating that ventricular tissue with an area as small as 100 mm 2 is capable of undergoing sustained fibrillatory activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.85.2.174

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 166

Metadata

Authors
Vaidya, D., Morley, G. E., Samie, F. H., & Jalife, J.
Venue
Circulation Research
Published
1999-07-23
Volume
85
Issue
2
Pages
174-181
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2140544589
Cited by
166
References
1
FWCI
7.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reentry and Fibrillation in the Mouse Heart: A Challenge to the Critical Mass Hypothesis. https://app.cochat.ai/papers/10.1161/01.res.85.2.174
The paper
Vaidya, D., Morley, G. E., Samie, F. H., & Jalife, J. (1999). Reentry and Fibrillation in the Mouse Heart: A Challenge to the Critical Mass Hypothesis. Circulation Research. https://doi.org/10.1161/01.res.85.2.174

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.