The DOI matches its Crossref record.
Oxygen Sensitivity of Cloned Voltage-Gated K+Channels Expressed in the Pulmonary Vasculature
Abstract
Abstract—Hypoxic pulmonary vasoconstriction is initiated by inhibiting one or more voltage-gated potassium (Kv) channel in the vascular smooth muscle cells (VSMCs) of the small pulmonary resistance vessels. Although progress has been made in identifying which Kv channel proteins are expressed in pulmonary arterial (PA) VSMCs, there are conflicting reports regarding which channels contribute to the native O 2-sensitive K+current. In this study, we examined the effects of hypoxia on the Kv1.2, Kv1.5, Kv2.1, and Kv9.3 α subunits expressed in mouse L cells using the whole-cell patch-clamp technique. Hypoxia (P o2=≈30 mm Hg) reversibly inhibited Kv1.2 and Kv2.1 currents only at potentials more positive than 30 mV. In contrast, hypoxia did not alter Kv1.5 current. Currents generated by coexpression of Kv2.1 with Kv9.3 α subunits were reversibly inhibited by hypoxia in the voltage range of the resting membrane potential (E M) of PA VSMCs (≈28% at −40 mV). Coexpression of Kv1.2 and Kv1.5 α subunits produced currents that displayed kinetic and pharmacological properties distinct from Kv1.2 and Kv1.5 channels expressed alone. Moreover, hypoxia reversibly inhibited Kv1.2/Kv1.5 current activated at physiologically relevant membrane potentials (≈65% at −40 mV). These results indicate that (1) hypoxia reversibly inhibits Kv1.2 and Kv2.1 but not Kv1.5 homomeric channels, (2) Kv1.2 and 1.5 α subunits can assemble to form an O 2-sensitive heteromeric channel, and (3) only Kv1.2/Kv1.5 and Kv2.1/Kv9.3 heteromeric channels are inhibited by hypoxia in the voltage range of the PA VSMC E M. Thus, these heteromeric channels are strong candidates for the K+channel isoforms initiating hypoxic pulmonary vasoconstriction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wei, A. D., Gutman, G. A., Aldrich, R., Chandy, K. G., Grissmer, S., & Wulff, H. (2005) · Pharmacological Reviews · doi:10.1124/pr.57.4.9 · Cited by 978
Hypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
Cellular Mechanism of Oxygen Sensing
López-Barneo, J., Pardal, R., & Ortega-Sáenz, P. (2001) · Annual Review of Physiology · doi:10.1146/annurev.physiol.63.1.259 · Cited by 544
Pozeg, Z. I., Michelakis, E. D., McMurtry, M. S., Thébaud, B., Wu, X.-C., Dyck, J. R. B., Hashimoto, K., Wang, S., Moudgil, R., Harry, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000062688.76508.b3 · Cited by 260
Regulation of oxygen sensing by ion channels
López-Barneo, J., del Toro, R., Levitsky, K. L., Chiara, M. D., & Ortega-Sáenz, P. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00929.2003 · Cited by 106
Metadata
- Authors
- Hulme, J. T., Coppock, E. A., Felipe, A., Martens, J. R., & Tamkun, M. M.
- Venue
- Circulation Research
- Published
- 1999-09-17
- Volume
- 85
- Issue
- 6
- Pages
- 489-497
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2155920800
- Cited by
- 161
- References
- 0
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen Sensitivity of Cloned Voltage-Gated K+Channels Expressed in the Pulmonary Vasculature. https://app.cochat.ai/papers/10.1161/01.res.85.6.489
- The paper
- Hulme, J. T., Coppock, E. A., Felipe, A., Martens, J. R., & Tamkun, M. M. (1999). Oxygen Sensitivity of Cloned Voltage-Gated K+Channels Expressed in the Pulmonary Vasculature. Circulation Research. https://doi.org/10.1161/01.res.85.6.489
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.