The DOI matches its Crossref record.
Distribution of Excitation Frequencies on the Epicardial and Endocardial Surfaces of Fibrillating Ventricular Wall of the Sheep Heart
Open accessAbstract
Abstract —Tissue heterogeneities may play an important role in the mechanism of ventricular tachycardia (VT) and fibrillation (VF) and can lead to a complex spatial distribution of excitation frequencies. Here we used optical mapping and Fourier analysis to determine the distribution of excitation frequencies in >20 000 sites of fibrillating ventricular tissue. Our objective was to use such a distribution as a tool to quantify the degree of organization during VF. Fourteen episodes of VT/VF were induced via rapid pacing in 9 isolated, coronary perfused, and superfused sheep ventricular slabs (3×3 cm 2 ). A dual-camera video-imaging system was used for simultaneous optical recordings from the entire epi- and endocardial surfaces. The local frequencies of excitation were determined at each pixel and displayed as dominant frequency (DF) maps. A typical DF map consisted of several (8.2±3.6) discrete areas (domains) with a uniform DF within each domain. The DFs in adjacent domains were often in 1:2, 3:4, or 4:5 ratios, which was shown to be a result of an intermittent Wenckebach-like conduction block at the domain boundaries. The domain patterns were relatively stable and could persist from several seconds to several minutes. The complexity in the organization of the domains, the number of domains, and the dispersion of frequencies increased with the rate of the arrhythmia. Domain patterns on the epicardial and endocardial surfaces were not correlated. Sustained epicardial or endocardial reentry was observed in only 3 episodes. Observed frequency patterns during VT/VF suggest that the underlying mechanism may be a sustained intramural reentrant source interacting with tissue heterogeneities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multiple mechanisms of spiral wave breakup in a model of cardiac electrical activity
Fenton, F. H., Cherry, E. M., Hastings, H. M., & Evans, S. J. (2002) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.1504242 · Cited by 559
Kalifa, J., Tanaka, K., Zaitsev, A. V., Warren, M., Vaidyanathan, R., Auerbach, D., Pandit, S., Vikstrom, K. L., Ploutz-Snyder, R., Talkachou, A., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.575340 · Cited by 414
Self-citationEfimov, I. R., Nikolski, V. P., & Salama, G. (2004) · Circulation Research · doi:10.1161/01.res.0000130529.18016.35 · Cited by 390
The Dynamics of Cardiac Fibrillation
Weiss, J. N., Qu, Z., Chen, P.-S., Lin, S.-F., Karagueuzian, H. S., Hayashi, H., Garfinkel, A., & Karma, A. (2005) · Circulation · doi:10.1161/circulationaha.104.529545 · Cited by 316
Samie, F. H., Berenfeld, O., Anumonwo, J., Mironov, S. F., Udassi, S., Beaumont, J., Taffet, S., Pertsov, A. M., & Jalife, J. (2001) · Circulation Research · doi:10.1161/hh2401.100818 · Cited by 293
Self-citation
Metadata
- Authors
- Zaitsev, A. V., Berenfeld, O., Mironov, S. F., Jalife, J., & Pertsov, A. M.
- Venue
- Circulation Research
- Published
- 2000-03-03
- Volume
- 86
- Issue
- 4
- Pages
- 408-417
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2147158087
- Cited by
- 238
- References
- 0
- FWCI
- 15.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distribution of Excitation Frequencies on the Epicardial and Endocardial Surfaces of Fibrillating Ventricular Wall of the Sheep Heart. https://app.cochat.ai/papers/10.1161/01.res.86.4.408
- The paper
- Zaitsev, A. V., Berenfeld, O., Mironov, S. F., Jalife, J., & Pertsov, A. M. (2000). Distribution of Excitation Frequencies on the Epicardial and Endocardial Surfaces of Fibrillating Ventricular Wall of the Sheep Heart. Circulation Research. https://doi.org/10.1161/01.res.86.4.408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.