Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 414

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Mechanisms of Wave Fractionation at Boundaries of High-Frequency Excitation in the Posterior Left Atrium of the Isolated Sheep Heart During Atrial Fibrillation

Open access
Kalifa, Jérôme, Tanaka, Kazuhiko, Zaitsev, Alexey V., Warren, Mark, Vaidyanathan, Ravi, Auerbach, David, Pandit, Sandeep, Vikstrom, Karen L., Ploutz-Snyder, Robert, Talkachou, Arkadzi, Atienza, Felipe, Guiraudon, Gérard, Jalife, José, Berenfeld, Omer·2006·Circulation

Abstract

Background— High-frequency fractionated electrograms recorded during atrial fibrillation (AF) in the posterior left atrium (PLA) and elsewhere are being used as target sites for catheter ablation. We tested the hypothesis that highly periodic electric waves emerging from AF sources at or near the PLA give rise to the most fractionated activity in adjacent locations. Methods and Results— Sustained AF was induced in 8 isolated sheep hearts (0.5 μmol/L acetylcholine). Endocardial videoimaging (DI-4-ANEPPS) and electric mapping of the PLA enabled spatial characterization of dominant frequencies (DFs) and a regularity index (ratio of DF to total power). Regularity index showed that fractionation was lowest within the area with the maximal DF (DFmax domain; 0.19±0.02) and highest within a band of &3 mm (0.16±0.02; P =0.047) at boundaries with lower-frequency domains. The numbers of spatiotemporal periodic episodes (25.9±2.3) and rotors per experiment (1.9±0.7) were also highest within the DFmax domain. Most commonly, breakthrough waves at the PLA traveled toward the rest of the atria (76.8±8.1% outward versus 23.2±8.1% inward; P <0.01). In both experiments and simulations with an atrial ionic model, fractionation at DFmax boundaries was associated with increased beat-to-beat variability of conduction velocity and directionality with wavebreak formation. Conclusions— During stable AF, the PLA harbors regular, fast, and highly organized activity; the outer limit of the DFmax domain is the area where the most propagation pattern variability and fractionated activity occur. These new concepts introduce a new perspective in the clinical use of high-frequency fractionated electrograms to localize sources of AF precisely at the PLA and elsewhere.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.575340

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 414

Metadata

Authors
Kalifa, J., Tanaka, K., Zaitsev, A. V., Warren, M., Vaidyanathan, R., Auerbach, D., Pandit, S., Vikstrom, K. L., Ploutz-Snyder, R., Talkachou, A., Atienza, F., Guiraudon, G., Jalife, J., & Berenfeld, O.
Venue
Circulation
Published
2006-02-07
Volume
113
Issue
5
Pages
626-633
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2110563082
Cited by
414
References
22
FWCI
21.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanisms of Wave Fractionation at Boundaries of High-Frequency Excitation in the Posterior Left Atrium of the Isolated Sheep Heart During Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/circulationaha.105.575340
The paper
Kalifa, J., Tanaka, K., Zaitsev, A. V., Warren, M., Vaidyanathan, R., Auerbach, D., Pandit, S., Vikstrom, K. L., Ploutz-Snyder, R., Talkachou, A., Atienza, F., Guiraudon, G., Jalife, J., & Berenfeld, O. (2006). Mechanisms of Wave Fractionation at Boundaries of High-Frequency Excitation in the Posterior Left Atrium of the Isolated Sheep Heart During Atrial Fibrillation. Circulation. https://doi.org/10.1161/circulationaha.105.575340

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.