Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High-Resolution Optical Mapping of the Right Bundle Branch in Connexin40 Knockout Mice Reveals Slow Conduction in the Specialized Conduction System

Tamaddon, Houman S., Vaidya, Dhananjay, Simon, Alexander M., Paul, David L., Jalife, José, Morley, Gregory E.·2000·Circulation Research

Abstract

Abstract —Connexin40 (Cx40) is a major gap junction protein that is expressed in the His-Purkinje system and thought to be a critical determinant of cell-to-cell communication and conduction of electrical impulses. Video maps of the ventricular epicardium and the proximal segment of the right bundle branch (RBB) were obtained using a high-speed CCD camera while simultaneously recording volume-conducted ECGs. In Cx40 –/– mice, the PR interval was prolonged (47.4±1.4 in wild-type [WT] [n=6] and 57.5±2.8 in Cx40 –/– [n=6]; P <0.01). WT ventricular epicardial activation was characterized by focused breakthroughs that originated first on the right ventricle (RV) and then the left ventricle (LV). In Cx40 –/– hearts, the RV breakthrough occurred after the LV breakthrough. Additionally, Cx40 –/– mice showed RV breakthrough times that were significantly delayed with respect to QRS complex onset (3.7±0.7 ms in WT [n=6] and 6.5±0.7 ms in Cx40 –/– [n=6]; P <0.01), whereas LV breakthrough times did not change. Conduction velocity measurements from optical mapping of the RBB revealed slow conduction in Cx40 –/– mice (74.5±3 cm/s in WT [n=7] and 43.7±6 cm/s in Cx40 –/– [n=7]; P <0.01). In addition, simultaneous ECG records demonstrated significant delays in Cx40 –/– RBB activation time with respect to P time (P-RBB time; 41.6±1.9 ms in WT [n=7] and 55.1±1.3 ms in [n=7]; P <0.01). These data represent the first direct demonstration of conduction defects in the specialized conduction system of Cx40 –/– mice and provide new insight into the role of gap junctions in cardiac impulse propagation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.87.10.929

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 160

Metadata

Authors
Tamaddon, H. S., Vaidya, D., Simon, A. M., Paul, D. L., Jalife, J., & Morley, G. E.
Venue
Circulation Research
Published
2000-11-10
Volume
87
Issue
10
Pages
929-936
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W1973174941
Cited by
160
References
1
FWCI
6.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Resolution Optical Mapping of the Right Bundle Branch in Connexin40 Knockout Mice Reveals Slow Conduction in the Specialized Conduction System. https://app.cochat.ai/papers/10.1161/01.res.87.10.929
The paper
Tamaddon, H. S., Vaidya, D., Simon, A. M., Paul, D. L., Jalife, J., & Morley, G. E. (2000). High-Resolution Optical Mapping of the Right Bundle Branch in Connexin40 Knockout Mice Reveals Slow Conduction in the Specialized Conduction System. Circulation Research. https://doi.org/10.1161/01.res.87.10.929

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.