Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 184

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Preoperative Diagnosis of Carotid Artery Stenosis: Accuracy of Noninvasive Testing

Open access
Nederkoorn, Paul J., Mali, Willem P.Th.M., Eikelboom, Bert C., Elgersma, Otto E.H., Buskens, Erik, Hunink, M.G. Myriam, Kappelle, L. Jaap, Buijs, Pieter C., Wüst, Aloys F.J., van der Lugt, Aad, van der Graaf, Yolanda·2002·Stroke

Abstract

Background and Purpose — Carotid endarterectomy has been shown to be beneficial in symptomatic patients with a severe stenosis (70% to 99%) of the internal carotid artery (ICA). Digital subtraction angiography (DSA) is the standard of reference in the diagnosis of carotid artery stenosis but has a relatively high complication rate. In a diagnostic study we investigated the accuracy of noninvasive testing compared with DSA. Methods — In a prospective diagnostic study we performed duplex ultrasound (DUS), magnetic resonance angiography (MRA), and DSA on 350 consecutive symptomatic patients. Stenoses were measured with the observers blinded for clinical information and other test results. Separate and combined test results of DUS and MRA were compared with the reference standard DSA. Only the stenosis measurements of the arteries on the symptomatic side were included in the analyses. Results — DUS analyzed with previously defined criteria resulted in a sensitivity of 87.5% (95% CI, 82.1% to 92.9%) and a specificity of 75.7% (95% CI, 69.3% to 82.2%) in identifying severe ICA stenosis (70% to 99%). Stenosis measurements on MRA yielded a sensitivity of 92.2% (95% CI, 86.2% to 96.2%) and a specificity of 75.7% (95% CI, 68.6% to 82.5%). When we combined MRA and DUS results, agreement between these 2 modalities (84% of patients) gave a sensitivity of 96.3% (95% CI, 90.8% to 99.0%) and a specificity of 80.2% (95% CI, 73.1% to 87.3%) for identifying severe stenosis. Conclusions — MRA showed a slightly better accuracy than DUS in the diagnosis of carotid artery stenosis. To achieve the best accuracy, however, both tests should be performed subsequently.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.0000021900.58396.44

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 184

Metadata

Authors
Nederkoorn, P. J., Mali, W. P. T. M., Eikelboom, B. C., Elgersma, O. E. H., Buskens, E., Hunink, M. G. M., Kappelle, L. J., Buijs, P. C., Wüst, A. F. J., van der Lugt, A., & van der Graaf, Y.
Venue
Stroke
Published
2002-08
Volume
33
Issue
8
Pages
2003-2008
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2163756482
Cited by
184
References
3
FWCI
11.74
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preoperative Diagnosis of Carotid Artery Stenosis: Accuracy of Noninvasive Testing. https://app.cochat.ai/papers/10.1161/01.str.0000021900.58396.44
The paper
Nederkoorn, P. J., Mali, W. P. T. M., Eikelboom, B. C., Elgersma, O. E. H., Buskens, E., Hunink, M. G. M., Kappelle, L. J., Buijs, P. C., Wüst, A. F. J., van der Lugt, A., & van der Graaf, Y. (2002). Preoperative Diagnosis of Carotid Artery Stenosis: Accuracy of Noninvasive Testing. Stroke. https://doi.org/10.1161/01.str.0000021900.58396.44

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.