Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 567

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Early Outcome of Carotid Angioplasty and Stenting With and Without Cerebral Protection Devices: A Systematic Review of the Literature

Kastrup, Andreas, Gröschel, Klaus, Krapf, Hilmar, Brehm, Bernhard R., Dichgans, Johannes, Schulz, Jörg B.·2003·Stroke

Abstract

Background— Carotid angioplasty and stenting (CAS) is increasingly being used for treatment of symptomatic and asymptomatic carotid artery disease (CAD). To evaluate the efficacy of cerebral protection devices in preventing thromboembolic complications during CAS, we conducted a systematic review of studies reporting on the incidence of minor stroke, major stroke, or death within 30 days after CAS. Summary of Review— We searched for studies published between January 1990 and June 2002 by means of a PubMed search and a cumulative review of reference lists of all relevant publications. In 2357 patients a total of 2537 CAS procedures had been performed without protection devices, and in 839 patients 896 CAS procedures had been performed with protection devices. Both groups were similar with respect to age, sex distribution, cerebrovascular risk factors, and indications for CAS. In many studies the periprocedural complication rates had not been presented separately for patients with symptomatic and asymptomatic CAD. The combined stroke and death rate within 30 days in both symptomatic and asymptomatic patients was 1.8% in patients treated with cerebral protection devices compared with 5.5% in patients treated without cerebral protection devices (χ 2 =19.7, P <0.001). This effect was mainly due to a decrease in the occurrence of minor strokes (3.7% without cerebral protection versus 0.5% with cerebral protection; χ 2 =22.4, P <0.001) and major strokes (1.1% without cerebral protection versus 0.3% with cerebral protection; χ 2 =4.3, P <0.05), whereas death rates were almost identical (≈0.8%; χ 2 =0.3, P =0.6). Conclusions— On the basis of this early analysis of single-center studies, the use of cerebral protection devices appears to reduce thromboembolic complications during CAS. These technical aspects should be taken into account before the initiation of further randomized trials comparing CAS with carotid endarterectomy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.0000058160.53040.5f

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Cited by

See all 567

Metadata

Authors
Kastrup, A., Gröschel, K., Krapf, H., Brehm, B. R., Dichgans, J., & Schulz, J. B.
Venue
Stroke
Published
2003-03
Volume
34
Issue
3
Pages
813-819
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2139799421
Cited by
567
References
35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early Outcome of Carotid Angioplasty and Stenting With and Without Cerebral Protection Devices: A Systematic Review of the Literature. https://app.cochat.ai/papers/10.1161/01.str.0000058160.53040.5f
The paper
Kastrup, A., Gröschel, K., Krapf, H., Brehm, B. R., Dichgans, J., & Schulz, J. B. (2003). Early Outcome of Carotid Angioplasty and Stenting With and Without Cerebral Protection Devices: A Systematic Review of the Literature. Stroke. https://doi.org/10.1161/01.str.0000058160.53040.5f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.