The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.
Guidelines and Recommendations for Perfusion Imaging in Cerebral Ischemia: A Scientific Statement for Healthcare Professionals by the Writing Group on Perfusion Imaging, From the Council on Cardiovascular Radiology of the American Heart Association
Open accessAbstract
A number of techniques have been developed during the past four decades to evaluate cerebral perfusion.The oldest used 133 Xe, a lipophilic radioactive tracer that easily diffuses through the blood-brain barrier (BBB).It was either injected or inhaled, and probes placed over the scalp were used to measure perfusion to the cerebral cortex.1,2 In the mid-1970s, the development of a scanner to detect the emission of positrons led to positron emission tomography (PET) in humans.3 Using a number of radioisotopes, this technology can measure cerebral blood flow (CBF) and various metabolic processes, but until recently it has been primarily used as a research tool.Stable ("cold") xenon was found to attenuate x-rays in a manner similar to iodine, and there were a number of projects in the 1970s to use this gas as a contrast agent for the rapidly emerging technology of computed tomography (CT), particularly as a perfusion tracer.4 This resulted in the development of the xenon-enhanced CT (XeCT) technique to calculate CBF in patients.5 With improvements in single photon emission CT (SPECT) during the 1980s, a number of compounds that are metabolized in the central nervous system (CNS) were found to be appropriate for perfusion imaging.6,7 Perfusion-weighted and diffusionweighted magnetic resonance (MR) imaging (PWI and DWI) were developed in the late 1980s, 8,9 and that technology has continued to improve.Finally, with the evolution of helical and spiral multislice CT technology, CT perfusion (CTP) imaging is becoming a potentially important clinical technique.10 Although the development of these technologies has been fascinating, their role in evaluating a variety of diseases of the CNS is controversial.It might seem obvious that a disorder of blood flow, such as acute stroke or chronic vascular occlusive disease, should be studied with a perfusion imaging technique.The accuracy, reproducibility, and reliability of the data from these techniques have been evaluated in animal models and in general have been found to be of very high quality.Their roles in predicting patient outcome and their use in planning treatment have received varying levels of scientific scrutiny.One of the purposes of this report is to assess the quality of such studies to determine the grade of recommendation that can be made for their use today and to guide the direction of future research.The rules of evidence for evaluating the quality and reliability of diagnostic tests such as perfusion imaging must obviously differ from those used to evaluate clinical studies.A committee of the American Academy of Neurology developed a scheme of evidence classification for diagnostic testing to evaluate reports of techniques that test the vestibular system.11 However, imaging studies differ from other types of diagnostic tests in important ways, because the data must often be interpreted by subjective rather than purely objective criteria.In addition, adequate clinical history is often necessary for an appropriate interpretation to be made.One way to assess the accuracy of an imaging study such as perfusion imaging is to gauge its ability to predict outcome, with or without subsequent treatment.This outcome may not be actual patient outcome but may be an outcome related to the tissue in question, such as the development of infarction.Another method of evaluation, possibly of even more importance, is an assessment of the ability of the information derived from the imaging test to influence the selection of subsequent medical management.For perfusion imaging, the ideal impartial assessment of the The American Heart Association makes every effort to avoid any actual or potential conflicts of interest that may arise as a result of an outside relationship or a personal, professional, or business interest of a member of the writing panel.Specifically, all members of the writing group are required to complete and submit a Disclosure Questionnaire showing all such relationships that might be perceived as real or potential conflicts of interest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data
Patlak, C. S., Blasberg, R. G., & Fenstermacher, J. D. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.1 · Cited by 3,567
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Thresholds of focal cerebral ischemia in awake monkeys
Jones, T. H., Morawetz, R. B., Crowell, R. M., Marcoux, F. W., FitzGibbon, S. J., DeGirolami, U., & Ojemann, R. G. (1981) · Journal of Neurosurgery · doi:10.3171/jns.1981.54.6.0773 · Cited by 1,159
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Diffusion-weighted MR Imaging of the Brain
Schaefer, P. W., Grant, P. E., & Gonzalez, R. G. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv24331 · Cited by 1,052
Larrue, V., von Kummer, R., Müller, A., & Bluhmki, E. (2001) · Stroke · doi:10.1161/01.str.32.2.438 · Cited by 1,006
(2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.45-12.s8 · Cited by 890
Cited by
Adams, H. P., Adams, R. J., Brott, T., del Zoppo, G. J., Furlan, A., Goldstein, L. B., Grubb, R. L., Higashida, R., Kidwell, C., Kwiatkowski, T. G., et al. (2003) · Stroke · doi:10.1161/01.str.0000064841.47697.22 · Cited by 1,245
Self-citationComparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Self-citationAlberts, M. J., Latchaw, R. E., Selman, W. R., Shephard, T., Hadley, M. N., Brass, L. M., Koroshetz, W., Marler, J. R., Booss, J., Zorowitz, R. D., et al. (2005) · Stroke · doi:10.1161/01.str.0000170622.07210.b4 · Cited by 585
Self-citationLatchaw, R. E., Alberts, M. J., Lev, M. H., Connors, J. J., Harbaugh, R. E., Higashida, R. T., Hobson, R., Kidwell, C. S., Koroshetz, W. J., Mathews, V., et al. (2009) · Stroke · doi:10.1161/strokeaha.108.192616 · Cited by 452
Self-citationAdams, H., Adams, R., Del Zoppo, G., & Goldstein, L. B. (2005) · Stroke · doi:10.1161/01.str.0000163257.66207.2d · Cited by 423
Metadata
- Authors
- Latchaw, R. E., Yonas, H., Hunter, G. J., Yuh, W. T. C., Ueda, T., Sorensen, A. G., Sunshine, J. L., Biller, J., Wechsler, L., Higashida, R., & Hademenos, G.
- Venue
- Stroke
- Published
- 2003-04
- Volume
- 34
- Issue
- 4
- Pages
- 1084-1104
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2111135913
- Cited by
- 319
- References
- 114
- FWCI
- 13.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Guidelines and Recommendations for Perfusion Imaging in Cerebral Ischemia: A Scientific Statement for Healthcare Professionals by the Writing Group on Perfusion Imaging, From the Council on Cardiovascular Radiology of the American Heart Association. https://app.cochat.ai/papers/10.1161/01.str.0000064840.99271.9e
- The paper
- Latchaw, R. E., Yonas, H., Hunter, G. J., Yuh, W. T. C., Ueda, T., Sorensen, A. G., Sunshine, J. L., Biller, J., Wechsler, L., Higashida, R., & Hademenos, G. (2003). Guidelines and Recommendations for Perfusion Imaging in Cerebral Ischemia: A Scientific Statement for Healthcare Professionals by the Writing Group on Perfusion Imaging, From the Council on Cardiovascular Radiology of the American Heart Association. Stroke. https://doi.org/10.1161/01.str.0000064840.99271.9e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.