The DOI matches its Crossref record.
Correlation of Quantitative EEG in Acute Ischemic Stroke With 30-Day NIHSS Score: Comparison With Diffusion and Perfusion MRI
Abstract
Background and Purpose— Magnetic resonance imaging (MRI) methods such as diffusion- (DWI) and perfusion-weighted (PWI) imaging have been widely studied as surrogate markers to monitor stroke evolution and predict clinical outcome. The utility of quantitative electroencephalography (qEEG) as such a marker in acute stroke has not been intensively studied. The aim of the present study was to correlate ischemic cortical stroke patients’ clinical outcomes with acute qEEG, DWI, and PWI data. Materials and Methods— DWI and PWI data were acquired from 11 patients within 7 and 16 hours after onset of symptoms. Sixty-four channel EEG data were obtained within 2 hours after the initial MRI scan and 1 hour before the second MRI scan. The acute delta change index (aDCI), a measure of the rate of change of average scalp delta power, was compared with the National Institutes of Health Stroke Scale scores (NIHSSS) at 30 days, as were MRI lesion volumes. Results— The aDCI was significantly correlated with the 30-day NIHSSS, as was the initial mean transit time (MTT) abnormality volume (ρ=0.80, P <0.01 and ρ=0.79, P <0.01, respectively). Modest correlations were obtained between the 15-hour DWI lesion volume and both the aDCI and 30-day NIHSSS (ρ=0.62, P <0.05 and ρ=0.73, P <0.05, respectively). Conclusions— In this small sample the significant correlation between 30-day NIHSSS and acute qEEG data (aDCI) was equivalent to that between the former and MTT abnormality volume. Both were greater than the modest correlation between acute DWI lesion volume and 30-day NIHSSS. These preliminary results indicate that acute qEEG data might be used to monitor and predict stroke evolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantitative EEG for the detection of brain ischemia
Foreman, B., & Claassen, J. (2012) · Critical Care · doi:10.1186/cc11230 · Cited by 315
Finnigan, S., & van Putten, M. J. A. M. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.07.003 · Cited by 310
Self-citationTuning pathological brain oscillations with neurofeedback: a systems neuroscience framework
Ros, T., J. Baars, B., Lanius, R. A., & Vuilleumier, P. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.01008 · Cited by 258
Mediterranean diet and healthy ageing: a Sicilian perspective
Vasto, S., Buscemi, S., Barera, A., Di Carlo, M., Accardi, G., & Caruso, C. (2014) · Gerontology · doi:10.1159/000363060 · Cited by 94
Mutschler, J., Abbruzzese, E., von der Goltz, C., Dinter, C., Mobascher, A., Thiele, H., Diaz-Lacava, A., Dahmen, N., Gallinat, J., Majic, T., et al. (2012) · European Addiction Research · doi:10.1159/000338276 · Cited by 17
Metadata
- Authors
- Finnigan, S. P., Rose, S. E., Walsh, M., Griffin, M., Janke, A. L., McMahon, K. L., Gillies, R., Strudwick, M. W., Pettigrew, C. M., Semple, J., Brown, J., Brown, P., & Chalk, J. B.
- Venue
- Stroke
- Published
- 2004-04
- Volume
- 35
- Issue
- 4
- Pages
- 899-903
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2126521277
- Cited by
- 199
- References
- 0
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation of Quantitative EEG in Acute Ischemic Stroke With 30-Day NIHSS Score: Comparison With Diffusion and Perfusion MRI. https://app.cochat.ai/papers/10.1161/01.str.0000122622.73916.d2
- The paper
- Finnigan, S. P., Rose, S. E., Walsh, M., Griffin, M., Janke, A. L., McMahon, K. L., Gillies, R., Strudwick, M. W., Pettigrew, C. M., Semple, J., Brown, J., Brown, P., & Chalk, J. B. (2004). Correlation of Quantitative EEG in Acute Ischemic Stroke With 30-Day NIHSS Score: Comparison With Diffusion and Perfusion MRI. Stroke. https://doi.org/10.1161/01.str.0000122622.73916.d2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.