Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Aggressive Mechanical Clot Disruption: A Safe Adjunct to Thrombolytic Therapy in Acute Stroke?

Open access
Noser, Elizabeth A., Shaltoni, Hashem M., Hall, Christiana E., Alexandrov, Andrei V., Garami, Zsolt, Cacayorin, Edwin D., Song, Joon K., Grotta, James C., Campbell, Morgan S. · 2005 · Stroke

Abstract

Background and Purpose— This study evaluated the safety and efficacy of aggressive mechanical clot disruption (AMCD) in acute stroke patients with persisting middle cerebral artery (MCA) or internal carotid artery (ICA) occlusion after thrombolytic therapy. Methods— Retrospective case series were used from a prospectively collected stroke database on consecutive acute ischemic stroke patients treated with intra-arterial (IA) thrombolytics and mechanical clot disruption during a 5-year interval. Thrombolytic dosage, endovascular techniques, immediate and final recanalization rates, symptomatic hemorrhage, mortality, and outcome were determined. Results— Thirty-two patients received AMCD. Median baseline National Institutes of Health Stroke Scale (NIHSS) score was 18, and median time to initiation of IA treatment was 261 minutes from symptom onset. ICA occlusion was noted in 16 patients and MCA occlusion in 16 patients: 22 received combined IV/IA thrombolytics, 3 received IV thrombolytics, 6 received IA thrombolytics, and 1 patient received no thrombolytics before AMCD. No immediate periprocedural complications were noted. Immediate recanalization was achieved in 38% (50% MCA, 25% ICA) and final recanalization in 75% (88% MCA, 63% ICA) of patients. Favorable outcome occurred in 19 (59%) patients, symptomatic cerebral hemorrhage in 3 (9.4%) patients, and mortality in 4 (12.5%) patients. Conclusion— AMCD can be performed safely with comparable intracerebral hemorrhage and mortality rates to other IA therapies even after use of intravenous thrombolytics in selected patients. Early deployment of this technique leads to immediate recanalization in one third of patients. AMCD may potentially shorten the time to flow restoration and improve overall recanalization rates achieved with IA therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.0000152331.93770.18

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
Noser, E. A., Shaltoni, H. M., Hall, C. E., Alexandrov, A. V., Garami, Z., Cacayorin, E. D., Song, J. K., Grotta, J. C., & Campbell, M. S.
Venue
Stroke
Published
2005-02
Volume
36
Issue
2
Pages
292-296
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2124858463
Cited by
182
References
1
FWCI
4.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aggressive Mechanical Clot Disruption: A Safe Adjunct to Thrombolytic Therapy in Acute Stroke? https://app.cochat.ai/papers/10.1161/01.str.0000152331.93770.18
The paper
Noser, E. A., Shaltoni, H. M., Hall, C. E., Alexandrov, A. V., Garami, Z., Cacayorin, E. D., Song, J. K., Grotta, J. C., & Campbell, M. S. (2005). Aggressive Mechanical Clot Disruption: A Safe Adjunct to Thrombolytic Therapy in Acute Stroke? Stroke. https://doi.org/10.1161/01.str.0000152331.93770.18

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.