The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ultrasonic evaluation of early carotid atherosclerosis.
Abstract
We investigated the prevalence of carotid atherosclerosis, including mild early lesions, and its association with cervical bruits and various risk factors (age, male sex, hypertension, hyperlipidemia, diabetes mellitus, obesity, and cigarette smoking) in 232 consecutive Japanese patients. High-resolution real-time B-mode ultrasonography was performed to determine the extent of atherosclerosis, and it was quantified by using a scoring system. The prevalence of carotid atherosclerosis was 49%, 59%, and 41% in all 232 patients, the 100 symptomatic patients, and the 132 asymptomatic patients, respectively. Although carotid lesions were detected frequently (87%) in the 30 patients with cervical bruits, bruits were noted in only 30% of the 88 examined patients with carotid atherosclerosis. Independent risk factors for carotid atherosclerosis in these patients were found to be age, male sex, and hyperlipidemia; diabetes mellitus was a possible risk factor for carotid atherosclerosis. Our study did not show a close association between hypertension and carotid atherosclerosis, and this might be caused by the high prevalence of hypertension in our patients. Our findings suggest an increasing prevalence of carotid atherosclerosis in the Japanese, though this should be confirmed in a population-based study. Our study demonstrates the clinical usefulness of high-resolution B-mode ultrasonography for the evaluation of early carotid atherosclerosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging.
Pignoli, P., Tremoli, E., Poli, A., Oreste, P., & Paoletti, R. (1986) · Circulation · doi:10.1161/01.cir.74.6.1399 · Cited by 2,404
Cited by
Long-Term Calorie Restriction Is Highly Effective in Reducing the Risk for Atherosclerosis in Humans
Fontana, L., Meyer, T. E., Klein, S., & Holloszy, J. O. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0308291101 · Cited by 902
Carotid Intima-Media Thickness and Plaque in Cardiovascular Risk Assessment
Naqvi, T. Z., & Lee, M.-S. (2014) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2013.11.014 · Cited by 649
Kronenberg, F., Kronenberg, M. F., Kiechl, S., Trenkwalder, E., Santer, P., Oberhollenzer, F., Egger, G., Utermann, G., & Willeit, J. (1999) · Circulation · doi:10.1161/01.cir.100.11.1154 · Cited by 293
Cardio-Ankle Vascular Index is a Candidate Predictor of Coronary Atherosclerosis
Nakamura, K., Tomaru, T., Yamamura, S., Miyashita, Y., Shirai, K., & Noike, H. (2007) · Circulation Journal · doi:10.1253/circj.72.598 · Cited by 269
Carotid Intima-Media Thickness and Risk of Cardiovascular Events in High-Risk Patients
Kitagawa, K., Hougaku, H., Yamagami, H., Hashimoto, H., Itoh, T., Shimizu, Y., Takahashi, D., Murata, S., Seike, Y., Kondo, K., et al. (2007) · Cerebrovascular Diseases · doi:10.1159/000103114 · Cited by 94
Self-citation
Metadata
- Authors
- Handa, N., Matsumoto, M., Maeda, H., Hougaku, H., Ogawa, S., Fukunaga, R., Yoneda, S., Kimura, K., & Kamada, T.
- Venue
- Stroke
- Published
- 1990-11
- Volume
- 21
- Issue
- 11
- Pages
- 1567-1572
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2090439216
- Cited by
- 416
- References
- 1
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonic evaluation of early carotid atherosclerosis. https://app.cochat.ai/papers/10.1161/01.str.21.11.1567
- The paper
- Handa, N., Matsumoto, M., Maeda, H., Hougaku, H., Ogawa, S., Fukunaga, R., Yoneda, S., Kimura, K., & Kamada, T. (1990). Ultrasonic evaluation of early carotid atherosclerosis. Stroke. https://doi.org/10.1161/01.str.21.11.1567
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.