The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Detection of arterial emboli using Doppler ultrasound in rabbits.
Open accessAbstract
The purpose of this study was to develop an animal model that could be used to test the ability of Doppler ultrasound to detect arterial emboli composed of materials that are often involved in cerebral emboli. Emboli introduced into the rabbit aorta via the left renal artery consisted of clotted whole blood, platelets, atheromatous material, fat, or air. The ultrasound examination was carried out continuously during the studies using a multifrequency transcranial Doppler apparatus with a 2-MHz probe, a sample volume of 15 mm, at a depth of 15 mm. The intensity of the Doppler spectrum was measured and displayed as a 15-shade color scale, each shade representing a 3-dB difference. The diameter of the aorta at the site of the ultrasound examination was similar to the diameter of the middle cerebral artery in humans. All 125 emboli introduced were clearly detected because they caused a Doppler signal at least 15 dB greater than that of the surrounding blood. These results show that the potential for emboli detection using Doppler ultrasound in the clinical situation is now considerable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microsurgical anatomy of the middle cerebral artery
Gibo, H., Carver, C. C., Rhoton, A. L., Lenkey, C., & Mitchell, R. J. (1981) · Journal of neurosurgery · doi:10.3171/jns.1981.54.2.0151 · Cited by 530
Cited by
Markus, H. S., Droste, D. W., Kaps, M., Larrue, V., Lees, K. R., Siebler, M., & Ringelstein, E. B. (2005) · Circulation · doi:10.1161/01.cir.0000163561.90680.1c · Cited by 754
The impact of microemboli during cardiopulmonary bypass on neuropsychological functioning.
Pugsley, W., Klinger, L., Paschalis, C., Treasure, T., Harrison, M., & Newman, S. (1994) · Stroke · doi:10.1161/01.str.25.7.1393 · Cited by 722
Markus, H. S., King, A., Shipley, M., Topakian, R., Cullinane, M., Reihill, S., Bornstein, N. M., & Schaafsma, A. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70120-4 · Cited by 437
Microemboli during coronary artery bypass grafting: Genesis and effect on outcome
Clark, R. E., Brillman, J., Davis, D. A., Lovell, M. R., Price, T. R. P., & Magovern, G. J. (1995) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(95)70386-1 · Cited by 321
Asymptomatic Embolization Predicts Stroke and TIA Risk in Patients With Carotid Artery Stenosis
Molloy, J., & Markus, H. S. (1999) · Stroke · doi:10.1161/01.str.30.7.1440 · Cited by 301
Metadata
- Authors
- Russell, D., Madden, K. P., Clark, W. M., Sandset, P. M., & Zivin, J. A.
- Venue
- Stroke
- Published
- 1991-02
- Volume
- 22
- Issue
- 2
- Pages
- 253-258
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2026593736
- Cited by
- 234
- References
- 1
- FWCI
- 13.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of arterial emboli using Doppler ultrasound in rabbits. https://app.cochat.ai/papers/10.1161/01.str.22.2.253
- The paper
- Russell, D., Madden, K. P., Clark, W. M., Sandset, P. M., & Zivin, J. A. (1991). Detection of arterial emboli using Doppler ultrasound in rabbits. Stroke. https://doi.org/10.1161/01.str.22.2.253
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.