Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Reproducibility of noninvasive ultrasonic measurement of carotid atherosclerosis. The Asymptomatic Carotid Artery Plaque Study.

Open access
Riley, W A, Barnes, R W, Applegate, W B, Dempsey, R, Hartwell, T, Davis, V G, Bond, M G, Furberg, C D·1992·Stroke

Abstract

To determine the effect of a lipid-lowering agent and/or a low-dose antithrombotic agent on the progression of early-stage carotid atherosclerosis, noninvasive B-mode ultrasound was used to measure intimal-medial thickness in asymptomatic individuals with moderately elevated lipids as part of the ongoing multicenter Asymptomatic Carotid Artery Plaque Study. Uniform ultrasonic scanning and reading protocols were implemented to obtain maximum intimal-medial thickness measurements in 12 standard segments in patients having a small to moderate wall thickness (1.5-3.5 mm) in at least one of the carotid arteries. Paired B-mode image recordings on 858 patients, performed 1 month apart and read at a core laboratory (each pair by the same reader), determined both within-sonographer (W, n = 405) and between-sonographer (B, n = 453) reproducibility. The primary end point (mean +/- SD), defined in each individual as the mean value of the 12 maximum intimal-medial thickness measurements, was 1.31 +/- 0.21 mm (W) and 1.32 +/- 0.22 (B) at the time of the second examination. The mean difference in the primary end point (exam 2-exam 1) was -0.01 +/- 0.13 mm (W) and 0.00 +/- 0.15 mm (B). The Pearson correlation coefficients were 0.79 (W) and 0.75 (B). In 90% of the patients, the absolute difference in the primary end point was less than 0.22 mm (W) and less than 0.24 mm (B). Variability of the secondary end point, defined as the single largest intimal-medial thickness measurement in a patient, was between three and four times larger than the variability for the primary end point. Differences in sonographer performance between clinical centers were very small. The results demonstrate that standardized noninvasive ultrasonic techniques yield highly reproducible measures of carotid intimal-medial thickness, which can serve as a measure of carotid atherosclerosis in clinical trials that monitor small rates of lesion progression.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.23.8.1062

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 215

Metadata

Authors
Riley, W. A., Barnes, R. W., Applegate, W. B., Dempsey, R., Hartwell, T., Davis, V. G., Bond, M. G., & Furberg, C. D.
Venue
Stroke
Published
1992-08
Volume
23
Issue
8
Pages
1062-1068
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2124582458
Cited by
215
References
2
FWCI
8.25
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of noninvasive ultrasonic measurement of carotid atherosclerosis. The Asymptomatic Carotid Artery Plaque Study. https://app.cochat.ai/papers/10.1161/01.str.23.8.1062
The paper
Riley, W. A., Barnes, R. W., Applegate, W. B., Dempsey, R., Hartwell, T., Davis, V. G., Bond, M. G., & Furberg, C. D. (1992). Reproducibility of noninvasive ultrasonic measurement of carotid atherosclerosis. The Asymptomatic Carotid Artery Plaque Study. Stroke. https://doi.org/10.1161/01.str.23.8.1062

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.