The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Reproducibility of noninvasive ultrasonic measurement of carotid atherosclerosis. The Asymptomatic Carotid Artery Plaque Study.
Open accessAbstract
To determine the effect of a lipid-lowering agent and/or a low-dose antithrombotic agent on the progression of early-stage carotid atherosclerosis, noninvasive B-mode ultrasound was used to measure intimal-medial thickness in asymptomatic individuals with moderately elevated lipids as part of the ongoing multicenter Asymptomatic Carotid Artery Plaque Study. Uniform ultrasonic scanning and reading protocols were implemented to obtain maximum intimal-medial thickness measurements in 12 standard segments in patients having a small to moderate wall thickness (1.5-3.5 mm) in at least one of the carotid arteries. Paired B-mode image recordings on 858 patients, performed 1 month apart and read at a core laboratory (each pair by the same reader), determined both within-sonographer (W, n = 405) and between-sonographer (B, n = 453) reproducibility. The primary end point (mean +/- SD), defined in each individual as the mean value of the 12 maximum intimal-medial thickness measurements, was 1.31 +/- 0.21 mm (W) and 1.32 +/- 0.22 (B) at the time of the second examination. The mean difference in the primary end point (exam 2-exam 1) was -0.01 +/- 0.13 mm (W) and 0.00 +/- 0.15 mm (B). The Pearson correlation coefficients were 0.79 (W) and 0.75 (B). In 90% of the patients, the absolute difference in the primary end point was less than 0.22 mm (W) and less than 0.24 mm (B). Variability of the secondary end point, defined as the single largest intimal-medial thickness measurement in a patient, was between three and four times larger than the variability for the primary end point. Differences in sonographer performance between clinical centers were very small. The results demonstrate that standardized noninvasive ultrasonic techniques yield highly reproducible measures of carotid intimal-medial thickness, which can serve as a measure of carotid atherosclerosis in clinical trials that monitor small rates of lesion progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Cardiovascular Health Study: design and rationale.
Fried, L. P., Borhani, N. O., Enright, P., Furberg, C. D., Gardin, J. M., Kronmal, R. A., Kuller, L. H., Manolio, T. A., Mittelmark, M. B., Newman, A., et al. (1991) · Annals of Epidemiology · doi:10.1016/1047-2797(91)90005-w · Cited by 3,652
Self-citationIntimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging.
Pignoli, P., Tremoli, E., Poli, A., Oreste, P., & Paoletti, R. (1986) · Circulation · doi:10.1161/01.cir.74.6.1399 · Cited by 2,404
Cited by
Biomarkers of Cardiovascular Disease: Molecular Basis and Practical Considerations
Vasan, R. S. (2006) · Circulation · doi:10.1161/circulationaha.104.482570 · Cited by 1,212
Davis, P. H., Dawson, J. D., Riley, W. A., & Lauer, R. M. (2001) · Circulation · doi:10.1161/hc4601.099486 · Cited by 884
Self-citationCardiovascular risk factors and cognitive decline in middle-aged adults
Knopman, D., Boland, L. L., Mosley, T., Howard, G., Liao, D., Szklo, M., McGovern, P., & Folsom, A. R. (2001) · Neurology · doi:10.1212/wnl.56.1.42 · Cited by 883
Vlachopoulos, C., Xaplanteris, P., Aboyans, V., Brodmann, M., Cífková, R., Cosentino, F., De Carlo, M., Gallino, A., Landmesser, U., Laurent, S., et al. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.05.007 · Cited by 716
Lonn, E. M., Yusuf, S., Dzavik, V., Doris, C. I., Yi, Q., Smith, S., Moore-Cox, A., Bosch, J., Riley, W. A., & Teo, K. K. (2001) · Circulation · doi:10.1161/01.cir.103.7.919 · Cited by 712
Self-citation
Metadata
- Authors
- Riley, W. A., Barnes, R. W., Applegate, W. B., Dempsey, R., Hartwell, T., Davis, V. G., Bond, M. G., & Furberg, C. D.
- Venue
- Stroke
- Published
- 1992-08
- Volume
- 23
- Issue
- 8
- Pages
- 1062-1068
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2124582458
- Cited by
- 215
- References
- 2
- FWCI
- 8.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of noninvasive ultrasonic measurement of carotid atherosclerosis. The Asymptomatic Carotid Artery Plaque Study. https://app.cochat.ai/papers/10.1161/01.str.23.8.1062
- The paper
- Riley, W. A., Barnes, R. W., Applegate, W. B., Dempsey, R., Hartwell, T., Davis, V. G., Bond, M. G., & Furberg, C. D. (1992). Reproducibility of noninvasive ultrasonic measurement of carotid atherosclerosis. The Asymptomatic Carotid Artery Plaque Study. Stroke. https://doi.org/10.1161/01.str.23.8.1062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.