Estimation of arterial stiffness, compliance, and distensibility from M-mode ultrasound measurements of the common carotid artery.

Open access
Gamble, G, Zorn, J, Sanders, G, MacMahon, S, Sharpe, N·1994·Stroke

Abstract

Arterial stiffness may indicate early vascular changes that predispose to the development of major vascular disease. The repeatability of a variety of indices of arterial stiffness calculated from a standard carotid arterial M-mode ultrasound image was investigated. Twenty-six asymptomatic normal subjects were imaged and had blood pressure recordings on each of two separate occasions at least 1 day apart. Using a computer-assisted method, the maximum and minimum internal diameter and average wall thickness of the right common carotid artery were measured over several cardiac cycles, and the following indices of arterial stiffness and distensibility (compliance) were derived: the pressure-strain elastic modulus (Ep), Young's modulus (E), cross-sectional compliance (CC), and the distensibility coefficient (DC). The repeatability of these measures, expressed as coefficients of variation, was as follows: Ep, 18%; E, 24%; CC, 14%; and DC, 13%. In another group of 20 subjects, the coefficient of variation for repeat examination by different sonographers was Ep, 19%; E, 20%; CC, 14%; and DC, 17% and for the one sonographer using two ultrasound machines was Ep, 13%; E, 13%; CC, 11%; and DC, 13%. These values indicate a moderate level of repeatability. In a univariate analysis each of these indices was significantly related to increasing age (Ep = 1.0 + 12.9 x AGE, r = .80; E = 314.5 + 13.9 x AGE, r = .48; CC = 22.6-0.26 x AGE, r = -.63; DC = 64.0-0.65 x AGE, r = -.78) but not to wall thickness (all P > .47). Using multiple regression techniques to adjust for age, wall thickness is a significant predictor of distensibility (P = .017), cross-sectional compliance (P < .001), and the pressure-strain elastic modulus (P = .019). Because Young's modulus is calculated from wall thickness, it could not be included in the multivariate analysis. We conclude that estimates of carotid artery distensibility and cross-sectional compliance derived from M-mode ultrasound recordings are moderately repeatable and may provide useful additional end points for trials of atherosclerotic progression.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.25.1.11

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Gamble, G., Zorn, J., Sanders, G., MacMahon, S., & Sharpe, N.
Venue
Stroke
Published
1994-01
Volume
25
Issue
1
Pages
11-16
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2163223476
Cited by
204
References
0
FWCI
1.80
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of arterial stiffness, compliance, and distensibility from M-mode ultrasound measurements of the common carotid artery. https://app.cochat.ai/papers/10.1161/01.str.25.1.11
The paper
Gamble, G., Zorn, J., Sanders, G., MacMahon, S., & Sharpe, N. (1994). Estimation of arterial stiffness, compliance, and distensibility from M-mode ultrasound measurements of the common carotid artery. Stroke. https://doi.org/10.1161/01.str.25.1.11

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.