The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Equivalence of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms. European Carotid Surgery Trialists' Collaborative Group.
Abstract
There is confusion about how carotid stenosis should be measured on angiograms. If the results of research based on different methods of measurement of stenosis are to be discussed and the results of clinical trials properly applied to routine clinical practice, measurements made by the different methods must be formally compared. The method of measurement of stenosis used in the European Carotid Surgery Trial (ECST), that used in the North American Symptomatic Carotid Endarterectomy Trial (NASCET), and a method based on measurement of the common carotid (CC) artery lumen diameter were compared. Carotid stenosis was measured by two observers, working independently and using the three different methods of measurement, on the angiographic view of the symptomatic carotid stenosis that showed the most severe disease in 1001 patients from the ECST. The results of using the ECST and CC methods differed from those of using the NASCET method in the classification of stenoses as mild (0% to 29%), moderate (30% to 69%), or severe (70% to 99%) in 51% of measurements. The ECST and CC methods indicated that twice as many stenoses were severe as did the NASCET method, and classified less than a third of the number of stenoses as mild. The results of the ECST and CC methods differed from each other in 15% of measurements. The relations between measurements made by each method to those made by the others were approximately linear, so a simple equation could be derived to convert measurements made by one method to measurements made by the others. There were major and clinically important disparities between measurements of stenosis made using different methods of measurement on the same angiograms. However, it is possible to convert measurements made by one method to those of another using a simple arithmetic equation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
(1991) · New England Journal of Medicine · doi:10.1056/nejm199108153250701 · Cited by 8,368
Cited by
Reanalysis of the Final Results of the European Carotid Surgery Trial
Rothwell, P. M., Gutnikov, S. A., & Warlow, C. P. (2003) · Stroke · doi:10.1161/01.str.0000054671.71777.c7 · Cited by 434
Self-citationPrediction of benefit from carotid endar terectomy in individual patients: a risk-modelling study
Rothwell, P., & Warlow, C. (1999) · The Lancet · doi:10.1016/s0140-6736(98)11415-0 · Cited by 411
Self-citationMRI findings of small subcortical “lacunar-like” infarction resulting from large vessel disease
Adachi, T., Kobayashi, S., Yamaguchi, S., & Okada, K. (2000) · Journal of Neurology · doi:10.1007/s004150050584 · Cited by 63
Metadata
- Authors
- Rothwell, P. M., Gibson, R. J., Slattery, J., Sellar, R. J., & Warlow, C. P.
- Venue
- Stroke
- Published
- 1994-12
- Volume
- 25
- Issue
- 12
- Pages
- 2435-2439
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2019487827
- Cited by
- 355
- References
- 1
- FWCI
- 11.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Equivalence of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms. European Carotid Surgery Trialists' Collaborative Group. https://app.cochat.ai/papers/10.1161/01.str.25.12.2435
- The paper
- Rothwell, P. M., Gibson, R. J., Slattery, J., Sellar, R. J., & Warlow, C. P. (1994). Equivalence of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms. European Carotid Surgery Trialists' Collaborative Group. Stroke. https://doi.org/10.1161/01.str.25.12.2435
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.