Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Prognostic value and reproducibility of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms. European Carotid Surgery Trialists' Collaborative Group.

Open access
Rothwell, P M, Gibson, R J, Slattery, J, Warlow, C P·1994·Stroke

Abstract

The use of three methods of measuring carotid stenosis, which produce different values on the same angiograms, has caused confusion and reduced the generalizability of the results of research. If the results of future studies are to be properly applied to clinical practice, and if noninvasive methods of imaging are to be properly validated against angiography, a single, standard method of measurement of stenosis on angiograms must be adopted. This standard method should be selected on the bases of its ability to predict risk of ipsilateral carotid distribution ischemic stroke and its reproducibility. The method of measurement of carotid stenosis used in the European Carotid Surgery Trial (ECST), that used in the North American Symptomatic Carotid Endarterectomy Trial (NASCET), and a method based on the measurement of the common carotid (CC) lumen diameter were studied. Their use in the prediction of ipsilateral carotid distribution ischemic stroke was assessed in 1001 consecutively selected patients randomly assigned to medical treatment in the ECST. Carotid stenosis was measured by two observers working independently, using all three methods, on the angiographic view that showed the most severe stenosis of the symptomatic carotid bifurcation. Interobserver agreement was determined, and 50 angiograms were remeasured to determine intraobserver agreement. There was little difference in the ability of the three methods to predict ipsilateral carotid distribution ischemic stroke. The CC method was consistently the most reproducible of the three, particularly for stenosis in the clinically important range of 50% to 90%. The CC method of measurement should be adopted as the standard method of measuring the degree of carotid stenosis on angiograms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.25.12.2440

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Rothwell, P. M., Gibson, R. J., Slattery, J., & Warlow, C. P.
Venue
Stroke
Published
1994-12
Volume
25
Issue
12
Pages
2440-2444
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2140859970
Cited by
158
References
2
FWCI
8.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prognostic value and reproducibility of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms. European Carotid Surgery Trialists' Collaborative Group. https://app.cochat.ai/papers/10.1161/01.str.25.12.2440
The paper
Rothwell, P. M., Gibson, R. J., Slattery, J., & Warlow, C. P. (1994). Prognostic value and reproducibility of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms. European Carotid Surgery Trialists' Collaborative Group. Stroke. https://doi.org/10.1161/01.str.25.12.2440

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.