Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 203

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Risk Factors and Segment-Specific Carotid Arterial Enlargement in the Atherosclerosis Risk in Communities (ARIC) Cohort

Crouse, John R., Goldbourt, Uri, Evans, Greg, Pinsky, Joan, Sharrett, A. Richey, Sorlie, Paul, Riley, Ward, Heiss, Gerardo · 1996 · Stroke

Abstract

Background and Purpose B-mode ultrasound imaging affords the opportunity to quantify both intimal-medial thickness (IMT) and lumen diameter of extracranial carotid arteries in ambulatory populations. Since the relation of IMT to lumen diameter may be complex, we asked whether cardiovascular disease risk factors (previously shown to be associated with greater arterial IMT) are related to smaller lumen diameters. Methods We used B-mode ultrasound to quantify lumen diameter, interadventitial diameter, and IMT of the extracranial carotid arteries and assessed the relationship of these measures to body mass index, smoking, low-density lipoprotein (LDL) and high-density lipoprotein cholesterol, hypertension, and diabetes in 6088 male and 7493 female participants in the Atherosclerosis Risk in Communities (ARIC) cohort. Results Smoking, hypertension, and LDL cholesterol were consistently related to greater IMT in the common and internal carotid arteries of men and women, as has been previously reported. In the internal carotid artery, smoking, hypertension, and LDL cholesterol were consistently related to smaller lumens. In the common carotid artery, body mass index, smoking, and hypertension were related to significantly larger, and LDL cholesterol to smaller, lumens. Thus, only LDL cholesterol was consistently associated with smaller lumens in both the common and internal carotid arteries. Conclusions Risk factors relate positively to IMT in both the common and internal carotid arteries and inversely with lumen diameter in the internal carotid artery, in parallel with their relation to clinical events. However, their association with lumen diameters of the common carotid artery in population-based samples is more complex, and in some cases adverse levels of risk factors may be associated with larger lumens.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.27.1.69

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 203

Metadata

Authors
Crouse, J. R., Goldbourt, U., Evans, G., Pinsky, J., Sharrett, A. R., Sorlie, P., Riley, W., & Heiss, G.
Venue
Stroke
Published
1996-01
Volume
27
Issue
1
Pages
69-75
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W1996660255
Cited by
203
References
2
FWCI
4.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.