The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Detection of Hyperacute Primary Intraparenchymal Hemorrhage by Magnetic Resonance Imaging
Abstract
Background MRI has become increasingly used in the acute setting to manage patients with stroke. There has been concern that MRI may not be sensitive in the detection of acute intracranial hemorrhage. We assessed whether strongly susceptibility-weighted MRI would be sensitive to intraparenchymal hemorrhage in the first few hours. Case Descriptions In the course of our ongoing studies of MRI of acute ischemic stroke in more than 200 patients, 35 patients had MR studies within 6 hours. Six of these patients who presented with acute focal symptoms with definite time of clinical onset (2.5 to 5 hours) were found to have evidence of intraparenchymal hemorrhage. Standard T 1 - and T 2 -weighted MR scans were performed. In 5 of the patients, echo-planar imaging and gradient-echo sequences were performed to increase the sensitivity of magnetic susceptibility effects of the pulse sequences. Four of the cases were of putaminal hemorrhage and 2 were lobar hemorrhages. The hemorrhage was most evident as foci of T 2 * hypointensity (signal loss) and unambiguous on the more susceptibility-weighted sequences, particularly echo-planar gradient-echo images. Conclusions MRI can detect hemorrhage within 2.5 to 5 hours of onset of clinical symptoms as regions of marked signal loss due to susceptibility effects, whereas conventional MR scans of ischemic stroke may appear normal. These results demonstrate that MR susceptibility sequences may be sensitive to hyperacute hemorrhage and suggest that MR may be an adequate screen for primary intraparenchymal hemorrhage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Cited by
Jauch, E. C., Saver, J. L., Adams, H. P., Bruno, A., Connors, J. J. (., Demaerschalk, B. M., Khatri, P., McMullan, P. W., Qureshi, A. I., Rosenfield, K., et al. (2013) · Stroke · doi:10.1161/str.0b013e318284056a · Cited by 7,634
Higashida, R. T., & Furlan, A. J. (2003) · Stroke · doi:10.1161/01.str.0000082721.62796.09 · Cited by 1,543
Chalela, J. A., Kidwell, C. S., Nentwich, L. M., Luby, M., Butman, J. A., Demchuk, A. M., Hill, M. D., Patronas, N., Latour, L., & Warach, S. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60151-2 · Cited by 1,301
Self-citationComparison of MRI and CT for Detection of Acute Intracerebral Hemorrhage
Kidwell, C. S. (2004) · JAMA · doi:10.1001/jama.292.15.1823 · Cited by 824
Antithrombotic and Thrombolytic Therapy for Ischemic Stroke
Albers, G. W., Easton, J. D., Sacco, R. L., & Teal, P. (1998) · Chest · doi:10.1378/chest.114.5_supplement.683s · Cited by 617
Metadata
- Authors
- Patel, M. R., Edelman, R. R., & Warach, S.
- Venue
- Stroke
- Published
- 1996-12
- Volume
- 27
- Issue
- 12
- Pages
- 2321-2324
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W1976776693
- Cited by
- 242
- References
- 1
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Hyperacute Primary Intraparenchymal Hemorrhage by Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1161/01.str.27.12.2321
- The paper
- Patel, M. R., Edelman, R. R., & Warach, S. (1996). Detection of Hyperacute Primary Intraparenchymal Hemorrhage by Magnetic Resonance Imaging. Stroke. https://doi.org/10.1161/01.str.27.12.2321
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.