The DOI matches its Crossref record.
Accuracy of ICD-9-CM Coding for the Identification of Patients With Acute Ischemic Stroke: Effect of Modifier Codes
Abstract
Background and Purpose —Discharge ICD-9-CM ( International Classification of Diseases, 9th Revision, Clinical Modification ) codes have been used to identify patients with acute stroke for epidemiological, quality of care, and cost studies. The aim of this study was to determine if the accuracy of the primary ICD-9-CM codes for ischemic stroke is improved by modifier codes and how specific codes reflect stroke subtype diagnoses. Methods —Available hospital charts for all patients discharged from a single hospital between May 1995 and June 1997 with ICD-9-CM codes 433 (occlusion and stenosis of precerebral arteries), 434 (occlusion of cerebral arteries), or 436 (acute but ill-defined cerebrovascular disease) listed in the first position were reviewed. The primary discharge diagnosis was verified, and a presumed stroke subtype was assigned on the basis of information provided in the medical record. Results —Charts were available for 175 of the 198 identified patients (88%). Of these, 61% had an acute ischemic stroke (code 433, 4%; 434, 82%; 436, 79%) with the remaining patients having other conditions. Of the 130 patients with a modifier code indicating cerebral infarction, 79% had an acute stroke; of the 45 patients with a modifier code indicating an absence of cerebral infarction, 7% had acute stroke (sensitivity, 0.97; specificity, 0.60). The codes with the highest proportions of ischemic stroke cases were 434.11 (embolic occlusion of cerebral arteries with infarction, 85%), 434.91 (unspecified occlusion of precerebral arteries with infarction, 82%), and 436 (79%), with a combined sensitivity of 0.81 and specificity of 0.90. On review, 73% of patients with code 434.11 had embolic strokes, and 47% of those with code 436 had an identified stroke cause. Of patients with code 434.91, 39% had stroke of uncertain cause, 25% “lacunar,” 17% atherothrombosis, and 15% embolism. Conclusions —Despite the use of modifier codes, 15% to 20% of patients with the indicated primary ICD-9-CM codes have conditions other than acute ischemic stroke. Although the proportion of patients with acute stroke increased from 61% to 79% with the use of modifier codes, the inclusion of modifier codes did not have an appreciable effect on the accuracy of the coding if patients with code 433 are excluded. Assignment of presumed ischemic stroke subtype is particularly inaccurate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Short term exposure to air pollution and stroke: systematic review and meta-analysis
Shah, A. S. V., Lee, K. K., McAllister, D. A., Hunter, A., Nair, H., Whiteley, W., Langrish, J. P., Newby, D. E., & Mills, N. L. (2015) · BMJ · doi:10.1136/bmj.h1295 · Cited by 870
“59 60 Secondly, many studies measured concentrations of air pollution at remote monitoring sites, and it is therefore likely there will be some degree of misclassification of exposure.”
BackgroundValidating Administrative Data in Stroke Research
Tirschwell, D. L., & Longstreth, W. T. (2002) · Stroke · doi:10.1161/01.str.0000032240.28636.bd · Cited by 658
National Clinical Guidelines for Stroke.
Robinson, T. (2001) · Postgraduate Medical Journal · doi:10.1136/pmj.77.906.286h · Cited by 608
Validity of diagnostic codes for acute stroke in administrative databases: a systematic review.
McCormick, N., Bhole, V., Lacaille, D., & Avina-Zubieta, J. A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0135834 · Cited by 414
Perioperative atrial fibrillation and the long-term risk of ischemic stroke
Gialdini, G., Nearing, K., Bhave, P. D., Bonuccelli, U., Iadecola, C., Healey, J. S., & Kamel, H. (2014) · JAMA · doi:10.1001/jama.2014.9143 · Cited by 355
Metadata
- Authors
- Goldstein, L. B.
- Venue
- Stroke
- Published
- 1998-08
- Volume
- 29
- Issue
- 8
- Pages
- 1602-1604
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2090728083
- Cited by
- 408
- References
- 0
- FWCI
- 23.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of ICD-9-CM Coding for the Identification of Patients With Acute Ischemic Stroke: Effect of Modifier Codes. https://app.cochat.ai/papers/10.1161/01.str.29.8.1602
- The paper
- Goldstein, L. B. (1998). Accuracy of ICD-9-CM Coding for the Identification of Patients With Acute Ischemic Stroke: Effect of Modifier Codes. Stroke. https://doi.org/10.1161/01.str.29.8.1602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.