Assessment of ≥50% and <50% Intracranial Stenoses by Transcranial Color-Coded Duplex Sonography

Open access
Baumgartner, Ralf W., Mattle, Heinrich P., Schroth, Gerhard · 1999 · Stroke

Abstract

Background and Purpose —A favorable risk-benefit ratio for warfarin compared with aspirin has been reported for the prevention of major vascular events in symptomatic ≥50% intracranial stenoses. Transcranial color-coded duplex sonography (TCCS) criteria providing an accurate detection of ≥50% and <50% stenoses of the anterior, middle, and posterior cerebral arteries and basilar and vertebral arteries were evaluated retrospectively with angiography used as the standard of reference. Methods —Prospectively collected TCCS, extracranial color-coded duplex sonography, and intra-arterial digital subtraction angiography data of 310 patients were reviewed. The patients had angiography for confirmation of symptomatic extracranial ≥70% carotid stenoses, symptomatic stenoses (peak systolic velocity higher than the corresponding mean value +2 SDs of 104 normal subjects), and occlusions of the middle cerebral or basilar artery previously assessed by ultrasound. The sonographer was not aware of angiographic findings. Results —TCCS would have detected all 31 of ≥50% intracranial stenoses with 1 false-positive and 35 of 38 <50% stenoses with 3 false-positives. One of 69 stenoses (1%) and 280 of 2741 normal arteries (10%) were missed because of inadequate insonation windows. The corresponding peak systolic velocity cutoffs for ≥50%/<50% stenoses were ≥155/≥120 cm/s (anterior cerebral artery), ≥220/≥155 cm/s (middle cerebral artery), ≥145/≥100 cm/s (posterior cerebral artery), ≥140/≥100 cm/s (basilar artery), and ≥120/≥90 cm/s (vertebral artery). Conclusions —TCCS may reliably assess ≥50% and <50% basal cerebral artery narrowing and prove useful for noninvasive management of patients with symptomatic intracranial stenoses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.30.1.87

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 289

Metadata

Authors
Baumgartner, R. W., Mattle, H. P., & Schroth, G.
Venue
Stroke
Published
1999-01
Volume
30
Issue
1
Pages
87-92
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2107686424
Cited by
289
References
18
FWCI
7.71
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of ≥50% and <50% Intracranial Stenoses by Transcranial Color-Coded Duplex Sonography. https://app.cochat.ai/papers/10.1161/01.str.30.1.87
The paper
Baumgartner, R. W., Mattle, H. P., & Schroth, G. (1999). Assessment of ≥50% and <50% Intracranial Stenoses by Transcranial Color-Coded Duplex Sonography. Stroke. https://doi.org/10.1161/01.str.30.1.87

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.