Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 239

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Frequency and Determinants of Postprocedural Hemodynamic Instability After Carotid Angioplasty and Stenting

Open access
Qureshi, Adnan I., Luft, Andreas R., Sharma, Mudit, Janardhan, Vallabh, Lopes, Demetrius K., Khan, Jehanzeb, Guterman, Lee R., Hopkins, L. Nelson · 1999 · Stroke

Abstract

Background and Purpose —Hemodynamic instability can occur acutely after carotid angioplasty and stent placement (CAS). We performed this study to determine the frequency of hemodynamic instability in a series of patients who underwent CAS and to analyze factors associated with development of postprocedural hemodynamic events. Methods —We reviewed medical records and angiograms in a series of 51 patients (mean age 68.3±8.9 years) who underwent CAS for symptomatic (n=29) or asymptomatic (n=22) carotid artery stenosis. Any episodes of hypotension (systolic blood pressure <90 mm Hg), hypertension (systolic blood pressure >160 mm Hg), or bradycardia (heart rate <60 bpm) that occurred in the acute postprocedural period were recorded. The effect of demographic, clinical, intraprocedural, and angiographic factors on subsequent development of hemodynamic instability was analyzed by logistic regression. Results —The frequency of postprocedural hemodynamic complications in our patient series was as follows: hypotension, 22.4%; hypertension, 38.8%; and bradycardia, 27.5%. Intraprocedural hypotension (odds ratio [OR] 14.6, P =0.024) and history of myocardial infarction (OR 14.1, P =0.04) independently predicted postprocedural hypotension. Postprocedural hypertension was predicted by intraprocedural hypertension (OR 7.6, P =0.01) and previous ipsilateral carotid endarterectomy (OR 7.6, P =0.02). Postprocedural bradycardia was associated with intraprocedural hypotension (OR 74, P =0.001) and intraprocedural bradycardia (OR 12, P =0.008). All events had resolved at the conclusion of the intensive care unit monitoring period (mean 25.7 hours, range 18 to 43 hours). Conclusions —Postprocedural hemodynamic instability is frequent after CAS and supports the need for monitoring in settings suited to expeditious management of cardiovascular emergencies. Patients who have evidence of hemodynamic instability during the procedure are at highest risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.30.10.2086

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 239

Metadata

Authors
Qureshi, A. I., Luft, A. R., Sharma, M., Janardhan, V., Lopes, D. K., Khan, J., Guterman, L. R., & Hopkins, L. N.
Venue
Stroke
Published
1999-10
Volume
30
Issue
10
Pages
2086-2093
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W1991193585
Cited by
239
References
2
FWCI
7.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.