In Vivo Fluorescence Imaging of Large-Vessel Thrombosis in Mice
Open accessThe DOI matches its Crossref record.
Abstract
Objective—: Experimental studies of large-vessel thrombosis have been adapted for applications in mice, but they proffer limited quantifiable information in outcome measures. This study presents a novel approach for evaluating large-vessel thrombogenesis with temporally/spatially quantifiable measures and normalization methods for interanimal comparisons. Methods and Results—: Shuttered, beam-expanded lasers provided uniform narrow-wavelength illumination of a ×100 microsurgical field with a large depth of focus. Thrombosis was generated in murine carotid arteries and femoral veins by brief vascular surface electrolytic injury. Thrombus-targeting fluorophores were injected systemically and subsequently localized at the site of thrombus induction. A low-light digital video camera with filter wheel provided target-specific image acquisition over a 60-minute interval. Platelets accumulated with a subsequent fibrin border emerging to stabilize the clot in both arteries and veins. Coagulation enzyme complexes colocalized with fibrin deposition. Large arteries underwent cyclic massive thromboembolization, whereas veins showed gradual shedding of microemboli and clot contraction. Systemic administration of fibrin- and platelet-inhibiting compounds reduced their respective targets but also often inhibited their clotting counterparts (platelets and fibrin, respectively) in both arteries and veins. Conclusion—: Intermediate-level magnified image capture represents a novel approach for analysis of fluorescence-based in vivo imaging, with quantitative application to the study of large-vessel thrombosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jain, A., Barrile, R., van der Meer, A., Mammoto, A., Mammoto, T., De Ceunynck, K., Aisiku, O., Otieno, M., Louden, C., Hamilton, G., et al. (2018) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.742 · Cited by 325
Jain, A., Graveline, A., Waterhouse, A., Vernet, A., Flaumenhaft, R., & Ingber, D. E. (2016) · Nature Communications · doi:10.1038/ncomms10176 · Cited by 182
“Based on the previous studies showing that the size of a growing thrombus measured in vitro correlates linearly with measured light intensity 41,42 , we can approximate that A max ¼ Sig ð t Þ , where A (t) is the cross-sectional area available for blood flow through the occluding channel at a given…”
BackgroundTissue factor–positive tumor microvesicles activate platelets and enhance thrombosis in mice
Geddings, J. E., Hisada, Y., Boulaftali, Y., Getz, T. M., Whelihan, M., Fuentes, R., Dee, R., Cooley, B. C., Key, N. S., Wolberg, A. S., et al. (2016) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13181 · Cited by 173
“Femoral and IVC thrombosis models were performed as described [37, 38].”
MethodSelf-citationAssessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium
Jain, A., van der Meer, A. D., Papa, A.-L., Barrile, R., Lai, A., Schlechter, B. L., Otieno, M. A., Louden, C. S., Hamilton, G. A., Michelson, A. D., et al. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0095-6 · Cited by 148
“Also was similar to that of clots formed on living endothelium in vivo, (Cooley 2011; Falati et al. 2002) and significantly different from those formed on bare collagen-coated flow chambers (shape of long tethers) (Colace et al. 2011) Taken together, these results demonstrate that the microfluidic…”
BackgroundResult
Metadata
- Authors
- Cooley, B. C.
- Venue
- Arteriosclerosis, Thrombosis, and Vascular Biology
- Published
- 2011-06
- Volume
- 31
- Issue
- 6
- Pages
- 1351-1356
- ISSN
- 1079-5642 (ISSN-L)
- 1524-4636
- OpenAlex
- W2100984089
- Cited by
- 74
- References
- 0
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Fluorescence Imaging of Large-Vessel Thrombosis in Mice. https://app.cochat.ai/papers/10.1161/atvbaha.111.225334
- The paper
- Cooley, B. C. (2011). In Vivo Fluorescence Imaging of Large-Vessel Thrombosis in Mice. Arteriosclerosis, Thrombosis, and Vascular Biology. https://doi.org/10.1161/atvbaha.111.225334
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.