Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium

Open access

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

The vascular endothelium and shear stress are critical determinants of physiological hemostasis and platelet function in vivo, yet current diagnostic and monitoring devices do not fully incorporate endothelial function under flow in their assessment and, therefore, they can be unreliable and inaccurate. It is challenging to include the endothelium in assays for clinical laboratories or point-of-care settings because living cell cultures are not sufficiently robust. Here, we describe a microfluidic device that is lined by a human endothelium that is chemically fixed, but still retains its ability to modulate hemostasis under continuous flow in vitro even after few days of storage. This device lined with a fixed endothelium supports formation of platelet-rich thrombi in the presence of physiological shear, similar to a living arterial vessel. We demonstrate the potential clinical value of this device by showing that thrombus formation and platelet function can be measured within minutes using a small volume (0.5 mL) of whole blood taken from subjects receiving antiplatelet medications. The inclusion of a fixed endothelial microvessel will lead to biomimetic analytical devices that can potentially be used for diagnostics and point-of-care applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10544-016-0095-6

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Engineering of the microfluidic device containing a chemically preserved endothelium. a Schematic of the microfluidic device showing a blood inlet reservoir, followed by the straight microchannel that ends at the outlet, where the syringe pump is attached to pull the blood, and b a photograph of a single polydimethylsiloxane (PDMS) microfluidic chip containing six independent microfluidic devices (bar, 15 mm) fabricated on a glass slide. c A fluorescence micrograph showing the entire microchannel covered with human umbilical vein endothelial cells (HUVECs) immunostained against the cell adhesion molecule, VE-cadherin (bar, 1 mm). d Confocal immunofluorescence microscopic images showing a section of the microchannel with HUVECs when viewed from above (‘xy’) and reconstruction of cross-sectional views from the front and the side (‘yz’ and ‘xz’, respectively) demonstrating full coverage of all microfluidic channel walls. (bottom; green, VE-Cadherin; blue, nuclear DAPI; bar, 200 μm). e–h Graph showing fluorescence (normalized by the untreated endothelium) measured after immunostaining the fixed endothelium with ICAM-1 (e), VCAM-1 (f), VWF (g), or tissue factor (h). *P < 0.05 versus untreated; n = 3
Fig. 1 Engineering of the microfluidic device containing a chemically preserved endothelium. a Schematic of the microfluidic device showing a blood inlet reservoir, followed by the straight microchannel that ends at the outlet, where the syringe pump is attached to pull the blood, and b a photograph of a single polydimethylsiloxane (PDMS) microfluidic chip containing six independent microfluidic devices (bar, 15 mm) fabricated on a glass slide. c A fluorescence micrograph showing the entire microchannel covered with human umbilical vein endothelial cells (HUVECs) immunostained against the cell adhesion molecule, VE-cadherin (bar, 1 mm). d Confocal immunofluorescence microscopic images showing a section of the microchannel with HUVECs when viewed from above (‘xy’) and reconstruction of cross-sectional views from the front and the side (‘yz’ and ‘xz’, respectively) demonstrating full coverage of all microfluidic channel walls. (bottom; green, VE-Cadherin; blue, nuclear DAPI; bar, 200 μm). e–h Graph showing fluorescence (normalized by the untreated endothelium) measured after immunostaining the fixed endothelium with ICAM-1 (e), VCAM-1 (f), VWF (g), or tissue factor (h). *P < 0.05 versus untreated; n = 3CC BY · PubMed Central
Fig. 2 Platelet coverage and fibrin formation on the fixed endothelium in the microdevice. a Representative maximum intensity projection micrographs showing fluorescently labeled platelets adhering to the fixed endothelium in a tumor necrosis factor (TNF-α) dose-dependent manner (bar, 100 μm). b Graph showing platelet coverage when blood is perfused inside the microchannel lined with a living or fixed endothelium that was stimulated by TNF-α before fixation. Comparison of living vs. fixed microchannels was not significantly different (P > 0.05) at each TNF-α concentration. (n = 4; *P < 0.05). c Fluorescent micrograph shows fibrin (green) is formed along with platelet aggregates (red) on a fixed endothelium that was pretreated with TNF-α and perfused with recalcified citrated whole blood (left, bar, 200 μm; right, bar, 20 μm)
Fig. 2 Platelet coverage and fibrin formation on the fixed endothelium in the microdevice. a Representative maximum intensity projection micrographs showing fluorescently labeled platelets adhering to the fixed endothelium in a tumor necrosis factor (TNF-α) dose-dependent manner (bar, 100 μm). b Graph showing platelet coverage when blood is perfused inside the microchannel lined with a living or fixed endothelium that was stimulated by TNF-α before fixation. Comparison of living vs. fixed microchannels was not significantly different (P > 0.05) at each TNF-α concentration. (n = 4; *P < 0.05). c Fluorescent micrograph shows fibrin (green) is formed along with platelet aggregates (red) on a fixed endothelium that was pretreated with TNF-α and perfused with recalcified citrated whole blood (left, bar, 200 μm; right, bar, 20 μm)CC BY · PubMed Central
Fig. 3 Assessment of antiplatelet therapy with the microfluidic device. a Platelet coverage on the fixed endothelium pretreated with TNF-α when blood samples containing different doses of the drug abciximab were perfused through the microfluidic device (n = 4) b Light transmission aggregometry of blood samples containing different doses of abciximab using either ADP or collagen as an agonist (n = 4). c Platelet coverage when blood samples containing different doses of the drug abciximab were perfused through collagen-coated microfluidic devices (n = 4). d Platelet coverage on the fixed endothelium pretreated with TNF-α when blood samples from healthy donors versus subjects treated with antiplatelet drugs were perfused through microfluidic devices (n = 11). e Light transmission aggregometry of healthy versus antiplatelet treated blood samples using ADP or collagen as an agonist (n = 11). f Platelet coverage when healthy versus subject blood samples were perfused through collagen-coated microfluidic devices (n = 11). *P < 0.05
Fig. 3 Assessment of antiplatelet therapy with the microfluidic device. a Platelet coverage on the fixed endothelium pretreated with TNF-α when blood samples containing different doses of the drug abciximab were perfused through the microfluidic device (n = 4) b Light transmission aggregometry of blood samples containing different doses of abciximab using either ADP or collagen as an agonist (n = 4). c Platelet coverage when blood samples containing different doses of the drug abciximab were perfused through collagen-coated microfluidic devices (n = 4). d Platelet coverage on the fixed endothelium pretreated with TNF-α when blood samples from healthy donors versus subjects treated with antiplatelet drugs were perfused through microfluidic devices (n = 11). e Light transmission aggregometry of healthy versus antiplatelet treated blood samples using ADP or collagen as an agonist (n = 11). f Platelet coverage when healthy versus subject blood samples were perfused through collagen-coated microfluidic devices (n = 11). *P < 0.05CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Research works printed but not linked: 3

  1. E. C. Lowenberg, J. C. Meijers, M. Levi, Neth. J. Med. 68, 242 (2010)
  2. T. G. Papaioannou, C. Stefanadis, Hell. J. Cardiol. HJC Hellēnikē Kardiologikē Epitheōrēsē 46, 9 (2005)
  3. F. Rossi, E. Rossi, F. I. Pareti, S. Colli, E. Tremoli, L. Gallo, Haematologica 86, 192 (2001)

Cited by

See all 152

Metadata

Authors
Jain, A., van der Meer, A. D., Papa, A.-L., Barrile, R., Lai, A., Schlechter, B. L., Otieno, M. A., Louden, C. S., Hamilton, G. A., Michelson, A. D., Frelinger, A. L., & Ingber, D. E.
Affiliations
  • Boston Children's Hospital (US)
  • Harvard University (US)
  • Cedars-Sinai Medical Center (US)
  • Carnegie Mellon University (US)
  • Beth Israel Deaconess Medical Center (US)
Corresponding author
Ingber, Donald E.
Venue
Biomedical Microdevices
Published
2016-07-27
Volume
18
Issue
4
Pages
73-73
ISSN
  • 1387-2176 (ISSN-L)
  • 1572-8781
OpenAlex
W2501166177
Cited by
148
References
32
Citations by year
2026: 9 · 2025: 10 · 2024: 18 · 2023: 12 · 2022: 11 · 2021: 22 · 2020: 17 · 2019: 15 · 2018: 17 · 2017: 15 · 2016: 1
FWCI
15.23
Type
journal article
Language
en
Open access
Licence
Locations
  • Biomedical Microdevices (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • University of Twente Research Information (submittedVersion, cc-by)
  • Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
  • University of Twente Research Information (submittedVersion, other-oa)
Funders
  • Defense Advanced Research Projects Agency (N66001-11-1-4180, HR0011-13-C-0025)
  • Janssen Pharmaceuticals
Topics
  • Health Sciences › Medicine › Hematology › Platelet Disorders and Treatments
  • Health Sciences › Medicine › Hematology › Blood properties and coagulation
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
microfluidics, platelet function, shear stress, hemostasis, platelet-rich thrombus, antiplatelet agents, point-of-care testing
MeSH terms
Blood Platelets, Endothelium, Vascular, Fibrin, Humans, Platelet Aggregation Inhibitors, Stress, Mechanical, Thrombosis, Point-of-Care Systems, Endothelial Cells, Lab-On-A-Chip Devices, Human Umbilical Vein Endothelial Cells

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium. https://app.cochat.ai/papers/10.1007/s10544-016-0095-6
The paper
Jain, A., van der Meer, A. D., Papa, A.-L., Barrile, R., Lai, A., Schlechter, B. L., Otieno, M. A., Louden, C. S., Hamilton, G. A., Michelson, A. D., Frelinger, A. L., & Ingber, D. E. (2016). Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium. Biomedical Microdevices. https://doi.org/10.1007/s10544-016-0095-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.