CoChat

Results of a Minimally Invasive Surgical Pulmonary Vein Isolation and Ganglionic Plexi Ablation for Atrial Fibrillation: Single-Center Experience With 12-Month Follow-Up

Han, Frederick T., Kasirajan, Vigneshwar, Kowalski, Marcin, Kiser, Robert, Wolfe, Luke, Kalahasty, Gautham, Shepard, Richard K., Wood, Mark A., Ellenbogen, Kenneth A. · 2009 · Circulation: Arrhythmia and Electrophysiology
Cited by 91

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background— The Cox Maze procedure for treatment of medically refractory atrial fibrillation (AF) is limited by its complexity and requirement for cardiopulmonary bypass. Long-term follow-up and success using criteria established by the Heart Rhythm Society/European Heart Rhythm Association/European Cardiac Arrhythmia Society consensus statement have not been reported for surgical AF ablation. We describe the results of using a thorascopic approach and radiofrequency energy to perform bilateral pulmonary vein isolation and left atrial ganglionic plexi ablation for treatment of AF. Methods and Results— Forty-five (33 paroxysmal; 12 persistent) consecutive patients underwent thorascopic bilateral radiofrequency pulmonary vein isolation, ganglionic plexi ablation, ligament of Marshall ablation, and left atrial appendage exclusion by a single surgeon. Forty-three patients were prospectively followed without antiarrhythmic drugs for a minimum of 1 year with a 30-day continuous event monitor or pacemaker interrogation at 6 and 12 months. Failure was defined as any atrial tachyarrhythmia of >30 seconds’ duration occurring >90 days after surgery. Mean follow-up was 516�181 days (202 to 858 days). Twenty-eight (65%) patients had no atrial tachyarrhythmia >30 seconds by 1 year, and 15 (35%) patients had atrial tachyarrhythmia recurrences by 1 year. Eight of 15 patients with recurrent AF had catheter ablation resulting in elimination and/or reduction of AF episodes in 7 of 8 patients. Four of 15 patients had AF elimination or reduction with antiarrhythmic drugs alone. Three patients did not benefit from surgery and received rate control only. There were no deaths; 1 phrenic nerve injury and 2 pleural effusions were the only major complications. Conclusions— The single procedure success at 1-year follow-up for surgical pulmonary vein isolation and ganglionic plexi ablation is 65%. Atrial tachyarrhythmia recurrences after surgery are usually responsive to catheter ablation and/or antiarrhythmic drugs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.109.854828

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 91

Metadata

Authors
Han, F. T., Kasirajan, V., Kowalski, M., Kiser, R., Wolfe, L., Kalahasty, G., Shepard, R. K., Wood, M. A., & Ellenbogen, K. A.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2009-08
Volume
2
Issue
4
Pages
370-377
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2154703743
Cited by
91
References
3
FWCI
8.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Results of a Minimally Invasive Surgical Pulmonary Vein Isolation and Ganglionic Plexi Ablation for Atrial Fibrillation: Single-Center Experience With 12-Month Follow-Up. https://app.cochat.ai/papers/10.1161/circep.109.854828
The paper
Han, F. T., Kasirajan, V., Kowalski, M., Kiser, R., Wolfe, L., Kalahasty, G., Shepard, R. K., Wood, M. A., & Ellenbogen, K. A. (2009). Results of a Minimally Invasive Surgical Pulmonary Vein Isolation and Ganglionic Plexi Ablation for Atrial Fibrillation: Single-Center Experience With 12-Month Follow-Up. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.109.854828

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.