CoChat

Low-Level Vagosympathetic Stimulation: A Paradox and Potential New Modality for the Treatment of Focal Atrial Fibrillation

Li, Shuyan, Scherlag, Benjamin J., Yu, Lilei, Sheng, Xia, Zhang, Ying, Ali, Reza, Dong, Yumei, Ghias, Muhammad, Po, Sunny S. · 2009 · Circulation: Arrhythmia and Electrophysiology
Cited by 122

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background— We used high-frequency stimulation delivered during the refractory period of the atrium and pulmonary veins (PVs) to induce focal firing and atrial fibrillation (AF). This study was designed to demonstrate that bilateral low-level vagosympathetic nerve stimulation (LL-VNS) could suppress high-frequency stimulation-induced focal AF at atrial and PV sites. Methods and Results— In 23 dogs anesthetized with Na-pentobarbital, electrodes in the vagosympathetic trunks allowed LL-VNS at 1 V below that which slowed the sinus rate or atrioventricular conduction. Multielectrode catheters were fixed at the right and left superior and inferior PVs and both atrial appendages. LL-VNS continued for 3 hours. At the end of each hour, the high-frequency stimulation algorithm consisting of a 40-ms train of stimuli (200 Hz; stimulus duration, 0.1 to 1.0 ms) was delivered 2 ms after the atrial pacing stimulus during the refractory period at each PV and atrial appendages site. The lowest voltage of high-frequency stimulation that induced AF was defined as the AF threshold. Five dogs without LL-VNS served as sham controls. Six dogs underwent LL-VNS after transection of bilateral vagosympathetic trunks. LL-VNS induced a progressive increase in AF threshold at all PV and atrial appendages sites, particularly significant ( P <0.05) at the right superior PV, right inferior PV, left superior PV, and right atrial appendage. Bilateral vagosympathetic transection did not significantly alter the previous findings, and the 5 sham control dogs did not show changes in AF threshold at any site over a period of 3 hours. Conclusions— LL-VNS may prevent episodic AF caused by rapid PV and non-PV firing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.109.868331

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 122

Metadata

Authors
Li, S., Scherlag, B. J., Yu, L., Sheng, X., Zhang, Y., Ali, R., Dong, Y., Ghias, M., & Po, S. S.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2009-12
Volume
2
Issue
6
Pages
645-651
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2155839723
Cited by
122
References
1
FWCI
4.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-Level Vagosympathetic Stimulation: A Paradox and Potential New Modality for the Treatment of Focal Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/circep.109.868331
The paper
Li, S., Scherlag, B. J., Yu, L., Sheng, X., Zhang, Y., Ali, R., Dong, Y., Ghias, M., & Po, S. S. (2009). Low-Level Vagosympathetic Stimulation: A Paradox and Potential New Modality for the Treatment of Focal Atrial Fibrillation. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.109.868331

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.