CoChat

Analysis of the Anatomical Tachycardia Circuit in Verapamil-Sensitive Atrial Tachycardia Originating From the Vicinity of the Atrioventricular Node

Open access
Yamabe, Hiroshige, Tanaka, Yasuaki, Morihisa, Kenji, Uemura, Takashi, Enomoto, Koji, Kawano, Hiroaki, Ogawa, Hisao · 2010 · Circulation: Arrhythmia and Electrophysiology
Cited by 32

The DOI matches its Crossref record.

Abstract

Background— Calcium channel–dependent tissue has been suggested to be involved in the circuit of verapamil-sensitive atrial tachycardia originating from the atrioventricular (AV) node vicinity (V-AT), but little information exists. Methods and Results— To examine the tachycardia circuit of V-AT, a single extrastimulus was delivered during tachycardia to 10 sites of the intraatrial septum: the earliest atrial activation site; His bundle (HB) site; 3 arbitrarily divided sites on the AV junction extending from the HB site to the coronary sinus ostium (CSOS) (sites S, M, and I); the internal-CSOS, inferior-CSOS, superior-CSOS, posterior-CSOS, and posteroinferior-CSOS in 10 patients with V-AT. The longest coupling interval that reset V-AT and subsequent return cycle were measured. The longest coupling interval at earliest atrial activation site was significantly longer than the longest coupling interval at the HB site, site S, M, and I, internal-CSOS, inferior-CSOS, superior-CSOS, posterior-CSOS, and posteroinferior-CSOS, respectively ( P <0.001 for HB site and P <0.0001 for the remaining 8 sites). The return cycle at earliest atrial activation site did not differ from the tachycardia cycle length, whereas those at the remaining 9 sites were significantly longer than tachycardia cycle length ( P <0.001). Furthermore, a single extrastimulus delivered from sites inferior to the HB site advanced His potential without resetting V-AT in 7 patients in whom AV block was not observed during tachycardia. Conclusions— Atrial tissue within the Koch’s triangle extending from the HB site to posteroinferior-CSOS is not involved in the tachycardia circuit. Verapamil-sensitive atrial tissue close to the AV node but not the AV nodal conducting system forms the tachycardia circuit of V-AT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.109.878678

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Yamabe, H., Tanaka, Y., Morihisa, K., Uemura, T., Enomoto, K., Kawano, H., & Ogawa, H.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2010-02
Volume
3
Issue
1
Pages
54-62
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2553419852
Cited by
32
References
0
FWCI
0.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.