Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 197

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Outcomes of Catheter Ablation of Ventricular Tachycardia in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy

Philips, Binu, Madhavan, Srinivasa, James, Cynthia, Tichnell, Crystal, Murray, Brittney, Dalal, Darshan, Bhonsale, Aditya, Nazarian, Saman, Judge, Daniel P., Russell, Stuart D., Abraham, Theodore, Calkins, Hugh, Tandri, Harikrishna · 2012 · Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: Prior studies evaluating the efficacy of catheter ablation of ventricular tachycardia (VT) among patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) have reported varied outcomes. More recently, studies have suggested that an epicardial ablation is necessary for improved outcomes after catheter ablation of VT. The overall objective of the present study was to assess the efficacy of radiofrequency catheter ablation (RFA) of VT in ARVD/C, with particular focus on newer ablation strategies, including epicardial catheter ablation. Methods and Results—: The study population included 87 patients with ARVD/C who underwent a total of 175 RFA procedures between 1992 and 2011 at 80 different electrophysiology centers. Recurrence of VT following RFA and effect of RFA on the burden of VT were assessed. The mean age of the cohort was 38 ± 13 years. Over a mean follow-up of 88.3 ± 66 months, the overall freedom from VT of the 175 procedures was 47%, 21%, and 15%, at 1, 5, and 10 years, respectively. The cumulative freedom from VT following epicardial RFA was 64% and 45% at 1 and 5 years, respectively, which was significantly longer than endocardial RFA ( P =0.021). Survival free of VT among procedures with 3D electroanatomic mapping was significantly longer compared to those without ( P =0.016). Burden of VT was reduced irrespective of the ablation strategy ( P <0.001). Conclusions—: Although VT recurrences are common, RFA results in a significant reduction in the burden of VT in patients with ARVD/C. Further, although the use of 3D electroanatomic mapping systems and epicardial ablation strategies are associated with longer survival free of VT, recurrence rates remain considerable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.111.968677

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 197

Metadata

Authors
Philips, B., Madhavan, S., James, C., Tichnell, C., Murray, B., Dalal, D., Bhonsale, A., Nazarian, S., Judge, D. P., Russell, S. D., Abraham, T., Calkins, H., & Tandri, H.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2012-06
Volume
5
Issue
3
Pages
499-505
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2551092810
Cited by
197
References
1
FWCI
11.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Outcomes of Catheter Ablation of Ventricular Tachycardia in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy. https://app.cochat.ai/papers/10.1161/circep.111.968677
The paper
Philips, B., Madhavan, S., James, C., Tichnell, C., Murray, B., Dalal, D., Bhonsale, A., Nazarian, S., Judge, D. P., Russell, S. D., Abraham, T., Calkins, H., & Tandri, H. (2012). Outcomes of Catheter Ablation of Ventricular Tachycardia in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.111.968677

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.