Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 181

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Time Course of Inflammation, Myocardial Injury, and Prothrombotic Response After Radiofrequency Catheter Ablation for Atrial Fibrillation

Lim, Han S., Schultz, Carlee, Dang, Jerry, Alasady, Muayad, Lau, Dennis H., Brooks, Anthony G., Wong, Christopher X., Roberts-Thomson, Kurt C., Young, Glenn D., Worthley, Matthew I., Sanders, Prashanthan, Willoughby, Scott R. · 2014 · Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: Inflammation has been linked to the genesis of stroke in atrial fibrillation (AF) and is implicated in early recurrent arrhythmia after AF ablation. We aimed to define the time course of inflammation, myocardial injury, and prothrombotic markers after radiofrequency ablation for AF and its relation to AF recurrence. Methods and Results—: Ninety consecutive AF patients (53% paroxysmal) undergoing radiofrequency ablation were recruited. High-sensitivity C-reactive protein (hs-CRP), Troponin-T, creatine kinase-MB, fibrinogen, and D-Dimer concentrations were measured at baseline, at 1, 2, 3, 7 days, and at 1 month after ablation. AF recurrence was documented at 3 days and at 1, 3, and 6 months follow-up. Troponin-T and creatine kinase-MB peaked at day 1 after procedure (both P <0.05). Hs-CRP peaked at day 3 after procedure ( P <0.05). Fibrinogen ( P <0.05) and D-Dimer ( P <0.05) concentrations were significantly elevated at 1 week after procedure. Ln hs-CRP elevation correlated with Ln Troponin-T and fibrinogen elevation. The extent of Ln hs-CRP, Ln Troponin-T, and fibrinogen elevation predicted early AF recurrence within 3 days after procedure ( P <0.05, respectively), but not at 3 and 6 months. Conclusions—: Patients undergoing radiofrequency ablation for AF exhibit an inflammatory response within 3 days. The extent of inflammatory response predicts early AF recurrence but not late recurrence. Prothrombotic markers are elevated at 1 week after ablation and may contribute to increased risk of early thrombotic events after AF ablation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.113.000876

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 181

Metadata

Authors
Lim, H. S., Schultz, C., Dang, J., Alasady, M., Lau, D. H., Brooks, A. G., Wong, C. X., Roberts-Thomson, K. C., Young, G. D., Worthley, M. I., Sanders, P., & Willoughby, S. R.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2014-02
Volume
7
Issue
1
Pages
83-89
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2034187191
Cited by
181
References
2
FWCI
8.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time Course of Inflammation, Myocardial Injury, and Prothrombotic Response After Radiofrequency Catheter Ablation for Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/circep.113.000876
The paper
Lim, H. S., Schultz, C., Dang, J., Alasady, M., Lau, D. H., Brooks, A. G., Wong, C. X., Roberts-Thomson, K. C., Young, G. D., Worthley, M. I., Sanders, P., & Willoughby, S. R. (2014). Time Course of Inflammation, Myocardial Injury, and Prothrombotic Response After Radiofrequency Catheter Ablation for Atrial Fibrillation. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.113.000876

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.