The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Unexpectedly High Incidence of Stroke and Left Atrial Appendage Thrombus Formation After Electrical Isolation of the Left Atrial Appendage for the Treatment of Atrial Tachyarrhythmias
Abstract
Background—: Electric left atrial appendage (LAA) isolation (LAAI) may occur during catheter ablation of atrial tachyarrhythmias. Data regarding the risk of thromboembolic events and stroke after LAAI are sparse. This study evaluated the incidence of LAA thrombus formation and thromboembolic events after LAAI. Methods and Results—: Fifty patients had LAAI (age=71 years; female=56%; CHA 2 DS 2 -VASc score before ablation =3 [2;3]). LAAI patients were compared with matched patients with comparable baseline characteristics who underwent atrial fibrillation ablation without LAAI (n=50). Ablation strategies in the LAAI group included pulmonary vein isolation in 50 (100%), left atrial isthmus line in 47 (94%), anterior line in 45 (90%), complex atrial fractionated potentials in 24 (48%), and roofline in 14 (28%) patients. Transesophageal echocardiography was performed during follow-up in 47/50 (94%) patients in the LAAI group and in all patients of the control group. Oral anticoagulation (OAC) independent of CHA 2 DS 2 -VASc score was strongly recommended in all patients. During a median follow-up of 6.5 (4–12) months, stroke occurred in 2 patients on OAC and transient ischemic attack in one without OAC in the LAAI group. In the remaining 47 patients, LAA thrombus was identified on transesophageal echocardiography in 10 (21%) patients (OAC=9; no OAC=1). In the control group, no LAA thrombus was detected and no stroke occurred ( P <0.001). Stable sinus rhythm was maintained in 32 patients (64%) of the LAAI group after a median follow-up of 6.5 months (4–12), including 17/32 patients on antiarrhythmic drugs. Conclusions—: After LAAI, an unexpectedly high incidence of LAA thrombus formation and stroke was observed despite OAC therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dabigatran versus warfarin in patients with atrial fibrillation
Connolly, S. J., Ezekowitz, M. D., Yusuf, S., Eikelboom, J., Oldgren, J., Parekh, A., Pogue, J., Reilly, P. A., Themeles, E., Varrone, J., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0905561 · Cited by 11,215
Rivaroxaban versus warfarin in nonvalvular atrial fibrillation
Patel, M. R., Mahaffey, K. W., Garg, J., Pan, G., Singer, D. E., Hacke, W., Breithardt, G., Halperin, J. L., Hankey, G. J., Piccini, J. P., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1009638 · Cited by 9,430
Apixaban in patients with atrial fibrillation
Connolly, S. J., Eikelboom, J., Joyner, C., Diener, H.-C., Hart, R., Golitsyn, S., Flaker, G., Avezum, A., Hohnloser, S. H., Diaz, R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1007432 · Cited by 2,483
Ouyang, F., Ernst, S., Vogtmann, T., Goya, M., Volkmer, M., Schaumann, A., Bänsch, D., Antz, M., & Kuck, K.-H. (2002) · Circulation · doi:10.1161/01.cir.0000015077.12680.2e · Cited by 212
Self-citation
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Stroke prevention in atrial fibrillation
Freedman, B., Potpara, T. S., & Lip, G. Y. H. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31257-0 · Cited by 463
EHRA/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion – an update
Glikson, M., Wolff, R., Hindricks, G., Mandrola, J., Camm, A. J., Lip, G. Y. H., Fauchier, L., Betts, T. R., Lewalter, T., Saw, J., et al. (2020) · EuroIntervention · doi:10.4244/eijy19m08_01 · Cited by 347
Metadata
- Authors
- Rillig, A., Tilz, R. R., Lin, T., Fink, T., Heeger, C.-H., Arya, A., Metzner, A., Mathew, S., Wissner, E., Makimoto, H., Wohlmuth, P., Kuck, K.-H., & Ouyang, F.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2016-05
- Volume
- 9
- Issue
- 5
- Pages
- e003461-e003461
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2345896385
- Cited by
- 200
- References
- 4
- FWCI
- 26.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unexpectedly High Incidence of Stroke and Left Atrial Appendage Thrombus Formation After Electrical Isolation of the Left Atrial Appendage for the Treatment of Atrial Tachyarrhythmias. https://app.cochat.ai/papers/10.1161/circep.115.003461
- The paper
- Rillig, A., Tilz, R. R., Lin, T., Fink, T., Heeger, C.-H., Arya, A., Metzner, A., Mathew, S., Wissner, E., Makimoto, H., Wohlmuth, P., Kuck, K.-H., & Ouyang, F. (2016). Unexpectedly High Incidence of Stroke and Left Atrial Appendage Thrombus Formation After Electrical Isolation of the Left Atrial Appendage for the Treatment of Atrial Tachyarrhythmias. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.115.003461
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.