CoChat

Prognostic Implications of Nonsustained Ventricular Tachycardia in High-Risk Patients With Hypertrophic Cardiomyopathy

Wang, Weijia, Lian, Zhesi, Rowin, Ethan J., Maron, Barry J., Maron, Martin S., Link, Mark S. · 2017 · Circulation: Arrhythmia and Electrophysiology
Cited by 100

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Background—: The prognostic significance of nonsustained ventricular tachycardia (NSVT) in patients with hypertrophic cardiomyopathy is incompletely resolved. Methods and Results—: The study group comprised 160 patients with implantable cardioverter defibrillators (ICDs), of whom 94 patients had 24- to 48-hour ambulatory monitoring preimplant. ICDs were interrogated and ambulatory ECGs monitored for NSVT episodes, with associations between NSVT- and ICD-treated ventricular arrhythmias examined. Eighty-six (54%) patients had runs of NSVT, including 17 before implant on ambulatory monitoring, 44 after ICD implantation, and 22 on both. Agreement between preimplant ambulatory monitoring and ICD interrogation for detecting NSVT was poor (κ=0.18). Eighteen of 86 patients (21%) with NSVT and 6 of 74 patients (8%) without NSVT experienced ICD-treated ventricular tachycardia (VT)/ventricular fibrillation (VF). NSVT was significantly associated with ICD-treated VT/VF (adjusted hazard ratio, 3.98; 95% confidence interval, 1.41–11.29; P =0.0093). ICD-treated VT/VF was associated with NSVT runs at a rate >200 beats per minute (adjusted hazard ratio, 15.63; 95% confidence interval, 4.01–60.89; P <0.0001) and >7 beats (adjusted hazard ratio, 6.26; 95% confidence interval, 2.02–19.41; P =0.0015). Repetitive runs of NSVT were also associated with ICD-treated VT/VF (adjusted hazard ratio, 9.22; 95% confidence interval, 2.53–33.60; P =0.0008). Slower (≤200 beats per minute), shorter (≤7), or a single run of NSVT were not associated with ICD-treated ventricular arrhythmias. Conclusions—: On extended monitoring, NSVT was independently associated with ICD-treated ventricular arrhythmias, supporting the importance of NSVT in hypertrophic cardiomyopathy risk stratification. Faster rate (>200 beats per minutes), longer (>7 beats), and repetitive runs of NSVT were more highly predictive of ICD-treated VT/VF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.116.004604

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 100

Metadata

Authors
Wang, W., Lian, Z., Rowin, E. J., Maron, B. J., Maron, M. S., & Link, M. S.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2017-03
Volume
10
Issue
3
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2597205879
Cited by
100
References
7
FWCI
7.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prognostic Implications of Nonsustained Ventricular Tachycardia in High-Risk Patients With Hypertrophic Cardiomyopathy. https://app.cochat.ai/papers/10.1161/circep.116.004604
The paper
Wang, W., Lian, Z., Rowin, E. J., Maron, B. J., Maron, M. S., & Link, M. S. (2017). Prognostic Implications of Nonsustained Ventricular Tachycardia in High-Risk Patients With Hypertrophic Cardiomyopathy. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.116.004604

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.